Cardiac Ejection Fraction and Volume Measurements Using Dynamic Cardiac Phantoms and Radionuclide Imaging

Publication ,  Journal Article
Jang, S; Jaszczak, RJ; Li, J; Evans, AJ; Greer, KL; Coleman, RE; Debatin, JF; Nadel, SN
Published in: IEEE Transactions on Nuclear Science
January 1, 1994

Dynamic cardiac phantoms and radionuclide imaging were used to obtain ejection fraction (EF) and left ventricular (LV) volume measurements. Tc-99m pertechnetate and water solutions were used to fill the ventricles, and 10 to 51 ml were added to the ventricular chambers so that 5 ejection fractions of 15% to 55% were produced. For planar and SPECT imaging a triple camera system with three different collimators, low energy high resolution (LEHR), ultra-high resolution (LEUR), and super high resolution (LESR) parallel beam collimators, were used. Three different collimators were chosen to evaluate the effects of different collimator resolutions on EF and LV volume measurements. The EF measurements from the planar images by three different collimators agree well with the actual EF within 10%. The volume estimations by pixel summing method produced the best estimations with a threshold of about 50% of the peak value within the ROI. In general, the lower the resolution of the collimator, the greater the deviation in the measured LV volume as the threshold level was changed, Overall, the count based method yielded the most reliable estimations in EF and volume measurements. The dynamic cardiac phantom is useful for evaluating methods for gated cardiac function measurements and studying collimator characteristics in cardiac imaging. © 1994 IEEE

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

IEEE Transactions on Nuclear Science

DOI

EISSN

1558-1578

ISSN

0018-9499

Publication Date

January 1, 1994

Volume

41

Issue

6

Start / End Page

2845 / 2849

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Jang, S., Jaszczak, R. J., Li, J., Evans, A. J., Greer, K. L., Coleman, R. E., … Nadel, S. N. (1994). Cardiac Ejection Fraction and Volume Measurements Using Dynamic Cardiac Phantoms and Radionuclide Imaging. IEEE Transactions on Nuclear Science, 41(6), 2845–2849. https://doi.org/10.1109/23.340656
Jang, S., R. J. Jaszczak, J. Li, A. J. Evans, K. L. Greer, R. E. Coleman, J. F. Debatin, and S. N. Nadel. “Cardiac Ejection Fraction and Volume Measurements Using Dynamic Cardiac Phantoms and Radionuclide Imaging.” IEEE Transactions on Nuclear Science 41, no. 6 (January 1, 1994): 2845–49. https://doi.org/10.1109/23.340656.
Jang S, Jaszczak RJ, Li J, Evans AJ, Greer KL, Coleman RE, et al. Cardiac Ejection Fraction and Volume Measurements Using Dynamic Cardiac Phantoms and Radionuclide Imaging. IEEE Transactions on Nuclear Science. 1994 Jan 1;41(6):2845–9.
Jang, S., et al. “Cardiac Ejection Fraction and Volume Measurements Using Dynamic Cardiac Phantoms and Radionuclide Imaging.” IEEE Transactions on Nuclear Science, vol. 41, no. 6, Jan. 1994, pp. 2845–49. Scopus, doi:10.1109/23.340656.
Jang S, Jaszczak RJ, Li J, Evans AJ, Greer KL, Coleman RE, Debatin JF, Nadel SN. Cardiac Ejection Fraction and Volume Measurements Using Dynamic Cardiac Phantoms and Radionuclide Imaging. IEEE Transactions on Nuclear Science. 1994 Jan 1;41(6):2845–2849.

Published In

IEEE Transactions on Nuclear Science

DOI

EISSN

1558-1578

ISSN

0018-9499

Publication Date

January 1, 1994

Volume

41

Issue

6

Start / End Page

2845 / 2849

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics