Skip to main content

Weighted backprojection implemented with a non-uniform attenuation map for improved spect quantitation

Publication ,  Journal Article
Manglos, SH; Jaszczak, RJ
Published in: IEEE Transactions on Nuclear Science
January 1, 1988

A method is developed to improve quantitation in SPECT imaging by using an attenuation compensation method which includes the correct non-uniform attenuation spatial distribution (“map“). The method is based on the technique of weighted back projection, previously developed for uniform attenuation. The method is tested by imaging a non-uniform phantom, reconstructing with the known attenuation map, and quantitatively comparing the resultant image with the known activity distribution. Reconstructed image profiles are dramatically improved in comparison to reconstructions without compensation or with an assumed uniform attenuation map. Contrast measurements further quantify the improvement. Line spread function distortions seen previously in non-uniform geometries are essentially eliminated by the method. Therefore, the method appears to be appropriate for these geometries, if the non-uniform map can be determined. Some additional image distortions introduced by the compensation method are noted and will require further study. © 1988 IEEE

Duke Scholars

Published In

IEEE Transactions on Nuclear Science

DOI

EISSN

1558-1578

ISSN

0018-9499

Publication Date

January 1, 1988

Volume

35

Issue

1

Start / End Page

625 / 628

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Manglos, S. H., & Jaszczak, R. J. (1988). Weighted backprojection implemented with a non-uniform attenuation map for improved spect quantitation. IEEE Transactions on Nuclear Science, 35(1), 625–628. https://doi.org/10.1109/23.12800
Manglos, S. H., and R. J. Jaszczak. “Weighted backprojection implemented with a non-uniform attenuation map for improved spect quantitation.” IEEE Transactions on Nuclear Science 35, no. 1 (January 1, 1988): 625–28. https://doi.org/10.1109/23.12800.
Manglos SH, Jaszczak RJ. Weighted backprojection implemented with a non-uniform attenuation map for improved spect quantitation. IEEE Transactions on Nuclear Science. 1988 Jan 1;35(1):625–8.
Manglos, S. H., and R. J. Jaszczak. “Weighted backprojection implemented with a non-uniform attenuation map for improved spect quantitation.” IEEE Transactions on Nuclear Science, vol. 35, no. 1, Jan. 1988, pp. 625–28. Scopus, doi:10.1109/23.12800.
Manglos SH, Jaszczak RJ. Weighted backprojection implemented with a non-uniform attenuation map for improved spect quantitation. IEEE Transactions on Nuclear Science. 1988 Jan 1;35(1):625–628.

Published In

IEEE Transactions on Nuclear Science

DOI

EISSN

1558-1578

ISSN

0018-9499

Publication Date

January 1, 1988

Volume

35

Issue

1

Start / End Page

625 / 628

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics