A technique was developed to align images from dynamic cardiac N-13 ammonia positron emission tomography (PET) scans. Inaccurate alignment of images from these scans stems from breathing, motion of the heart within the thorax, and overall motion of the patient (particularly during pharmacologie stress). The images from these scans represent changing distributions, from high blood pool concentrations to predominantly myocardial uptake, and are generally noisy. In this technique, templates are defined from a long, late frame (5-10 min). These templates include a myocardial template, which matches late frames, a blood pool template, which matches frames in which the left ventricle blood pool is dominant, and a modified blood pool template, which reduces the effect of activity in the right ventricle. The correlation function is used as the maximized parameter over shifts between each three-dimensional image frame and the appropriate template. The technique was tested on phantom, human, and animal data with myocardial defects. Phantom data showed the technique to be reliable to within one voxel (1.7 x 1.7 x 4.2 mm3 ), and motion which was apparent in human data was reduced significantly. Blood flow values measured from corrected data showed two traits: higher values, due to better matching regions of interest to images, and better fits, due to smoother time-activity curves. © 1997 IEEE.

Duke Scholars

Published In

IEEE Transactions on Nuclear Science

DOI

ISSN

0018-9499

Publication Date

December 1, 1997

Volume

44

Issue

2

Start / End Page

235 / 242

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Turkington, T. G., Degrado, T. R., Hanson, M. W., & Edward Coleman, R. (1997). Alignment of dynamic cardiac PET images for correction of motion. IEEE Transactions on Nuclear Science, 44(2), 235–242. https://doi.org/10.1109/23.568814
Turkington, T. G., T. R. Degrado, M. W. Hanson, and R. Edward Coleman. “Alignment of dynamic cardiac PET images for correction of motion.” IEEE Transactions on Nuclear Science 44, no. 2 (December 1, 1997): 235–42. https://doi.org/10.1109/23.568814.
Turkington TG, Degrado TR, Hanson MW, Edward Coleman R. Alignment of dynamic cardiac PET images for correction of motion. IEEE Transactions on Nuclear Science. 1997 Dec 1;44(2):235–42.
Turkington, T. G., et al. “Alignment of dynamic cardiac PET images for correction of motion.” IEEE Transactions on Nuclear Science, vol. 44, no. 2, Dec. 1997, pp. 235–42. Scopus, doi:10.1109/23.568814.
Turkington TG, Degrado TR, Hanson MW, Edward Coleman R. Alignment of dynamic cardiac PET images for correction of motion. IEEE Transactions on Nuclear Science. 1997 Dec 1;44(2):235–242.

Published In

IEEE Transactions on Nuclear Science

DOI

ISSN

0018-9499

Publication Date

December 1, 1997

Volume

44

Issue

2

Start / End Page

235 / 242

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics