Performance of a full-scale biotrickling filter treating H2S at a gas contact time of 1.6 to 2.2 seconds

Publication ,  Journal Article
Gabriel, D; Deshusses, MA
Published in: Environmental Progress
July 1, 2003

Emission of objectionable odors is a major problem for wastewater treatment and other processing facilities. Biological treatment is a promising alternative to conventional control methods, such as chemical scrubbing, but historically, biotreatment has always required significantly larger reactor volumes than chemical scrubbers. In this paper, we present several aspects to the operation and performance of a chemical scrubber, retrofitted to operate as a biotrickling filter treating 16,000 m3 h-1 of foul air with the original gas contact time of 1.6 to 2.2 seconds. In continuous operation for more than a year, the biotrickling filter has shown stable performance and robust behavior for H2S treatment, with pollutant removal performance comparable to using a chemical scrubber. Reclaimed water was used as a nutrient source for the process, and to maintain the pH in the biotrickling filter between 1.5 and 2.2. At a gas contact time of 1.6 seconds, H2S removal was in excess of 95% for sustained inlet H2S concentrations as high as 30 ppmv. This corresponds to volumetric elimination rates of 95 to 105 g H2S m-3 h-1. Efficiencies of about 90% were observed under transient conditions at 2.2 seconds gas contact time for inlet concentration peaks up to 60 ppmv. The biotrickling filter also removed significant amounts of reduced sulfur compounds, ammonia, and volatile organic compounds present in traces in the air, which is important in practical applications. Selected experiments, such as intermittent trickling operation and a one-month operation period at neural pH, are also presented. Results indicate that the intermittent trickling operation does not have a significant effect on H2S removal. However, when operated at neutral pH, biotrickling filter performance clearly decreased, probably due to an excessive chlorine supply to the reactor through the make-up water. The study demonstrates that biotrickling filters can replace chemical scrubbers as a safer, more economical technique for odor control.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Environmental Progress

DOI

ISSN

0278-4491

Publication Date

July 1, 2003

Volume

22

Issue

2

Start / End Page

111 / 118

Related Subject Headings

  • Environmental Sciences
  • 34 Chemical sciences
  • 31 Biological sciences
  • 06 Biological Sciences
  • 03 Chemical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Gabriel, D., & Deshusses, M. A. (2003). Performance of a full-scale biotrickling filter treating H2S at a gas contact time of 1.6 to 2.2 seconds. Environmental Progress, 22(2), 111–118. https://doi.org/10.1002/ep.670220213
Gabriel, D., and M. A. Deshusses. “Performance of a full-scale biotrickling filter treating H2S at a gas contact time of 1.6 to 2.2 seconds.” Environmental Progress 22, no. 2 (July 1, 2003): 111–18. https://doi.org/10.1002/ep.670220213.
Gabriel D, Deshusses MA. Performance of a full-scale biotrickling filter treating H2S at a gas contact time of 1.6 to 2.2 seconds. Environmental Progress. 2003 Jul 1;22(2):111–8.
Gabriel, D., and M. A. Deshusses. “Performance of a full-scale biotrickling filter treating H2S at a gas contact time of 1.6 to 2.2 seconds.” Environmental Progress, vol. 22, no. 2, July 2003, pp. 111–18. Scopus, doi:10.1002/ep.670220213.
Gabriel D, Deshusses MA. Performance of a full-scale biotrickling filter treating H2S at a gas contact time of 1.6 to 2.2 seconds. Environmental Progress. 2003 Jul 1;22(2):111–118.
Journal cover image

Published In

Environmental Progress

DOI

ISSN

0278-4491

Publication Date

July 1, 2003

Volume

22

Issue

2

Start / End Page

111 / 118

Related Subject Headings

  • Environmental Sciences
  • 34 Chemical sciences
  • 31 Biological sciences
  • 06 Biological Sciences
  • 03 Chemical Sciences