Skip to main content
construction release_alert
Scholars@Duke will be undergoing maintenance April 11-15. Some features may be unavailable during this time.
cancel

Axial strain measurements in skeletal muscle at various strain rates.

Publication ,  Journal Article
Best, TM; McElhaney, JH; Garrett, WE; Myers, BS
Published in: Journal of biomechanical engineering
August 1995

A noncontact optical system using high speed image analysis to measure local tissue deformations and axial strains along skeletal muscle is described. The spatial resolution of the system was 20 pixels/cm and the accuracy was +/- 0.125 mm. In order to minimize the error associated with discrete data used to characterize a continuous strain field, the displacement data were fitted with a third order polynomial and the fitted data differentiated to measure surface strains using a Lagrangian finite strain formulation. The distribution of axial strain along the muscle-tendon unit was nonuniform and rate dependent. Despite a variation in local strain distribution with strain rate, the maximum axial strain, Exx = 0.614 +/- 0.045 mm/mm, was rate insensitive and occurred at the failure site for all tests. The frequency response of the video system (1000 Hz) and the measurement of a continuous strain field along the entire length of the structure improve upon previous noncontact optical systems for measurement of surface strains in soft tissues.

Duke Scholars

Published In

Journal of biomechanical engineering

DOI

EISSN

1528-8951

ISSN

0148-0731

Publication Date

August 1995

Volume

117

Issue

3

Start / End Page

262 / 265

Related Subject Headings

  • Sprains and Strains
  • Rabbits
  • Muscle, Skeletal
  • Biomedical Engineering
  • Biomechanical Phenomena
  • Animals
  • 4003 Biomedical engineering
  • 0913 Mechanical Engineering
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Best, T. M., McElhaney, J. H., Garrett, W. E., & Myers, B. S. (1995). Axial strain measurements in skeletal muscle at various strain rates. Journal of Biomechanical Engineering, 117(3), 262–265. https://doi.org/10.1115/1.2794179
Best, T. M., J. H. McElhaney, W. E. Garrett, and B. S. Myers. “Axial strain measurements in skeletal muscle at various strain rates.Journal of Biomechanical Engineering 117, no. 3 (August 1995): 262–65. https://doi.org/10.1115/1.2794179.
Best TM, McElhaney JH, Garrett WE, Myers BS. Axial strain measurements in skeletal muscle at various strain rates. Journal of biomechanical engineering. 1995 Aug;117(3):262–5.
Best, T. M., et al. “Axial strain measurements in skeletal muscle at various strain rates.Journal of Biomechanical Engineering, vol. 117, no. 3, Aug. 1995, pp. 262–65. Epmc, doi:10.1115/1.2794179.
Best TM, McElhaney JH, Garrett WE, Myers BS. Axial strain measurements in skeletal muscle at various strain rates. Journal of biomechanical engineering. 1995 Aug;117(3):262–265.

Published In

Journal of biomechanical engineering

DOI

EISSN

1528-8951

ISSN

0148-0731

Publication Date

August 1995

Volume

117

Issue

3

Start / End Page

262 / 265

Related Subject Headings

  • Sprains and Strains
  • Rabbits
  • Muscle, Skeletal
  • Biomedical Engineering
  • Biomechanical Phenomena
  • Animals
  • 4003 Biomedical engineering
  • 0913 Mechanical Engineering
  • 0903 Biomedical Engineering