Stroke: who's counting what?

Published

Journal Article

INTRODUCTION: Patients with stroke are often selected for epidemiological reporting and research using ICD-9-CM (ICD-9) diagnostic codes. This study addresses the accuracy of these codes in identifying patients with stroke. METHODS: A sample of 279 patients with new stroke and 392 non-stroke (no evidence of new stroke) patients were identified by medical record review from 11 Veterans Affairs Medical Centers. Administrative records containing ICD-9-CM diagnoses were matched with this sample. Coding sensitivity and specificity were determined using individual ICD-9 codes and two coding algorithms. RESULTS: Significant variation was found in the accuracy of cerebrovascular ICD-9-CM codes in identifying patients diagnosed with stroke. Two coding algorithms were identified with the following performance statistics based on the sampled populations: 1) 91-percent sensitivity, 40-percent specificity; and 2) 54-percent sensitivity, 87-percent specificity. DISCUSSION/CONCLUSIONS: Variability in identifying patients with stroke using ICD-9 codes has been reported in the literature and confirmed. Two coding algorithms for maximizing sensitivity or specificity are proposed. Caution is urged when using ICD-9-coded administrative data to identify patients with stroke.

Full Text

Cited Authors

  • Reker, DM; Hamilton, BB; Duncan, PW; Yeh, SC; Rosen, A

Published Date

  • March 2001

Published In

Volume / Issue

  • 38 / 2

Start / End Page

  • 281 - 289

PubMed ID

  • 11392661

Pubmed Central ID

  • 11392661

Electronic International Standard Serial Number (EISSN)

  • 1938-1352

International Standard Serial Number (ISSN)

  • 0748-7711

Language

  • eng