Skip to main content
Journal cover image

Gating provides improved accuracy for differentiating artifacts from true lesions in equivocal fixed defects on technetium 99m tetrofosmin perfusion SPECT.

Publication ,  Journal Article
Choi, JY; Lee, KH; Kim, SJ; Kim, SE; Kim, BT; Lee, SH; Lee, WR
Published in: J Nucl Cardiol
1998

BACKGROUND: Because equivocal fixed perfusion defects on single photon emission computed tomography (SPECT) often cause a diagnostic dilemma in patients with suspected coronary artery disease (CAD), we used receiver-operating characteristic (ROC) curve analysis to evaluate the degree of increased accuracy provided by adding gated images for interpretation of such cases. METHODS AND RESULTS: One hundred five (29%) of 365 consecutive patients undergoing technetium 99m tetrofosmin gated SPECT for evaluation of CAD demonstrated an equivocal fixed defect. Two independent observers graded the probability for true lesion with a 5-point system over 3 steps of interpretation: reviewing tomographic images alone (step 1), adding projection images (step 2), and adding gated cine images (step 3). Based on clinical criteria, 66 patients were categorized as disease negative and 25 as disease positive, while the final diagnosis was undetermined in 14 cases. Diagnostic performance was significantly higher at step 3 than at step 1 for both observers (p < 0.05 and < 0.0001) and at step 2 for observer B (p < 0.005). The maximum accuracy increased from 78.0% to 80.2% at step 2 to 84.6% to 86.8% at step 3. Moreover, the agreement of interpretation between the 2 observers was higher at step 3 (kappa = 0.53) than at step 1 (kappa = 0.29) or step 2 (kappa = 0.25). CONCLUSION: In patients showing an equivocal fixed defect on 99mTc tetrofosmin SPECT, gated cine images provide improved differential accuracy and enhanced objectivity of interpretation by reducing interobserver variance.

Duke Scholars

Published In

J Nucl Cardiol

DOI

ISSN

1071-3581

Publication Date

1998

Volume

5

Issue

4

Start / End Page

395 / 401

Location

United States

Related Subject Headings

  • Tomography, Emission-Computed, Single-Photon
  • Sensitivity and Specificity
  • Radiopharmaceuticals
  • ROC Curve
  • Organotechnetium Compounds
  • Organophosphorus Compounds
  • Observer Variation
  • Middle Aged
  • Male
  • Image Processing, Computer-Assisted
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Choi, J. Y., Lee, K. H., Kim, S. J., Kim, S. E., Kim, B. T., Lee, S. H., & Lee, W. R. (1998). Gating provides improved accuracy for differentiating artifacts from true lesions in equivocal fixed defects on technetium 99m tetrofosmin perfusion SPECT. J Nucl Cardiol, 5(4), 395–401. https://doi.org/10.1016/s1071-3581(98)90145-3
Choi, J. Y., K. H. Lee, S. J. Kim, S. E. Kim, B. T. Kim, S. H. Lee, and W. R. Lee. “Gating provides improved accuracy for differentiating artifacts from true lesions in equivocal fixed defects on technetium 99m tetrofosmin perfusion SPECT.J Nucl Cardiol 5, no. 4 (1998): 395–401. https://doi.org/10.1016/s1071-3581(98)90145-3.
Choi, J. Y., et al. “Gating provides improved accuracy for differentiating artifacts from true lesions in equivocal fixed defects on technetium 99m tetrofosmin perfusion SPECT.J Nucl Cardiol, vol. 5, no. 4, 1998, pp. 395–401. Pubmed, doi:10.1016/s1071-3581(98)90145-3.
Journal cover image

Published In

J Nucl Cardiol

DOI

ISSN

1071-3581

Publication Date

1998

Volume

5

Issue

4

Start / End Page

395 / 401

Location

United States

Related Subject Headings

  • Tomography, Emission-Computed, Single-Photon
  • Sensitivity and Specificity
  • Radiopharmaceuticals
  • ROC Curve
  • Organotechnetium Compounds
  • Organophosphorus Compounds
  • Observer Variation
  • Middle Aged
  • Male
  • Image Processing, Computer-Assisted