Skip to main content

Ejection load changes in aortic stenosis. Observations made after balloon aortic valvuloplasty.

Publication ,  Journal Article
Shim, Y; Hampton, TG; Straley, CA; Harrison, JK; Spero, LA; Bashore, TM; Pasipoularides, AD
Published in: Circ Res
November 1992

To investigate complementarity and competitiveness between the intrinsic and extrinsic components of the total left ventricular systolic load, hemodynamic data from 18 elderly subjects with severe aortic stenosis were analyzed before and after balloon dilation of the stenosed aortic valve. Multisensor micromanometric pressure measurements allowed calculation (simplified Bernoulli equation) of the ejection velocity and aortic input impedance spectra. Despite a 32% increase in the aortic valve area (from 0.56 +/- 0.04 to 0.74 +/- 0.05 cm2 [mean +/- SEM], p < 0.01), the peak left ventricular systolic pressure fell by only 12% (from 189 +/- 10 to 167 +/- 8 mm Hg, p < 0.01). This was accompanied by an increase in the impedance at the same cardiac output. In a subset of patients (n = 9) in whom the peak aortic systolic pressure rose after valvuloplasty (from 115 +/- 10 to 128 +/- 12 mm Hg, p < 0.01), a 40% increase in the aortic valve area was accompanied by a marked increase in the aortic input impedance. In this subset, the steady component of the aortic input impedance increased by 24% (from 960 +/- 96 to 1,188 +/- 134 dyne.sec/ml, p < 0.05), and the characteristic impedance increased by 25% (from 106 +/- 13 to 132 +/- 19 dyne.sec/ml, p < 0.05). Because of an increased aortic impedance acutely following the procedure, the total left ventricular systolic load after balloon dilation of the stenotic valve was only slightly decreased despite a significant increase in aortic valve area. This represents an example of complementarity and competitiveness between the intrinsic and extrinsic components of the total systolic ventricular load. It may explain why improvement in left ventricular performance may be modest acutely following balloon aortic valvuloplasty.

Duke Scholars

Published In

Circ Res

DOI

ISSN

0009-7330

Publication Date

November 1992

Volume

71

Issue

5

Start / End Page

1174 / 1184

Location

United States

Related Subject Headings

  • Vascular Resistance
  • Stroke Volume
  • Postoperative Period
  • Male
  • Humans
  • Hemodynamics
  • Female
  • Catheterization
  • Cardiovascular System & Hematology
  • Blood Pressure
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Shim, Y., Hampton, T. G., Straley, C. A., Harrison, J. K., Spero, L. A., Bashore, T. M., & Pasipoularides, A. D. (1992). Ejection load changes in aortic stenosis. Observations made after balloon aortic valvuloplasty. Circ Res, 71(5), 1174–1184. https://doi.org/10.1161/01.res.71.5.1174
Shim, Y., T. G. Hampton, C. A. Straley, J. K. Harrison, L. A. Spero, T. M. Bashore, and A. D. Pasipoularides. “Ejection load changes in aortic stenosis. Observations made after balloon aortic valvuloplasty.Circ Res 71, no. 5 (November 1992): 1174–84. https://doi.org/10.1161/01.res.71.5.1174.
Shim Y, Hampton TG, Straley CA, Harrison JK, Spero LA, Bashore TM, et al. Ejection load changes in aortic stenosis. Observations made after balloon aortic valvuloplasty. Circ Res. 1992 Nov;71(5):1174–84.
Shim, Y., et al. “Ejection load changes in aortic stenosis. Observations made after balloon aortic valvuloplasty.Circ Res, vol. 71, no. 5, Nov. 1992, pp. 1174–84. Pubmed, doi:10.1161/01.res.71.5.1174.
Shim Y, Hampton TG, Straley CA, Harrison JK, Spero LA, Bashore TM, Pasipoularides AD. Ejection load changes in aortic stenosis. Observations made after balloon aortic valvuloplasty. Circ Res. 1992 Nov;71(5):1174–1184.

Published In

Circ Res

DOI

ISSN

0009-7330

Publication Date

November 1992

Volume

71

Issue

5

Start / End Page

1174 / 1184

Location

United States

Related Subject Headings

  • Vascular Resistance
  • Stroke Volume
  • Postoperative Period
  • Male
  • Humans
  • Hemodynamics
  • Female
  • Catheterization
  • Cardiovascular System & Hematology
  • Blood Pressure