Technical evaluation of a digital chest radiography system that uses a selenium detector.

Publication ,  Journal Article
Chotas, HG; Floyd, CE; Ravin, CE
Published in: Radiology
April 1995

PURPOSE: To evaluate a digital chest radiography system that uses a selenium detector. MATERIALS AND METHODS: The relative amounts of scattered radiation in the images (scatter fractions), the effect of x-ray exposure levels on image appearance, the potential "throughput" in a clinical environment, and the effects of image processing options were evaluated. RESULTS: Scatter fractions in digital images acquired with an antiscatter grid were lower in the lung region and higher in the retrocardiac and central mediastinal regions than in conventional images. Digital images acquired without an antiscatter grid had higher scatter fractions in all areas. Increases in exposure intensity reduced the appearance of noise. A new image could be acquired every 37 seconds, and a "preview image" appeared on the monitor after approximately 23 seconds. Laser-printed images were available after at least 5 minutes; the time required increased when many images were acquired in a short time. CONCLUSION: The selenium-based chest radiography system allows for rapid chest examination and excellent image quality when used with an antiscatter grid.

Duke Scholars

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

April 1995

Volume

195

Issue

1

Start / End Page

264 / 270

Location

United States

Related Subject Headings

  • Time Factors
  • Technology, Radiologic
  • Selenium
  • Scattering, Radiation
  • Radiography, Thoracic
  • Radiographic Image Enhancement
  • Nuclear Medicine & Medical Imaging
  • Lung Diseases
  • Humans
  • Evaluation Studies as Topic
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chotas, H. G., Floyd, C. E., & Ravin, C. E. (1995). Technical evaluation of a digital chest radiography system that uses a selenium detector. Radiology, 195(1), 264–270. https://doi.org/10.1148/radiology.195.1.7892483
Chotas, H. G., C. E. Floyd, and C. E. Ravin. “Technical evaluation of a digital chest radiography system that uses a selenium detector.Radiology 195, no. 1 (April 1995): 264–70. https://doi.org/10.1148/radiology.195.1.7892483.
Chotas HG, Floyd CE, Ravin CE. Technical evaluation of a digital chest radiography system that uses a selenium detector. Radiology. 1995 Apr;195(1):264–70.
Chotas, H. G., et al. “Technical evaluation of a digital chest radiography system that uses a selenium detector.Radiology, vol. 195, no. 1, Apr. 1995, pp. 264–70. Pubmed, doi:10.1148/radiology.195.1.7892483.
Chotas HG, Floyd CE, Ravin CE. Technical evaluation of a digital chest radiography system that uses a selenium detector. Radiology. 1995 Apr;195(1):264–270.
Journal cover image

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

April 1995

Volume

195

Issue

1

Start / End Page

264 / 270

Location

United States

Related Subject Headings

  • Time Factors
  • Technology, Radiologic
  • Selenium
  • Scattering, Radiation
  • Radiography, Thoracic
  • Radiographic Image Enhancement
  • Nuclear Medicine & Medical Imaging
  • Lung Diseases
  • Humans
  • Evaluation Studies as Topic