Skip to main content
Journal cover image

Efficacy of signal-averaged electrocardiography in the young orthotopic heart transplant patient to detect allograft rejection.

Publication ,  Journal Article
Horenstein, MS; Idriss, SF; Hamilton, RM; Kanter, RJ; Webster, PA; Karpawich, PP
Published in: Pediatr Cardiol
2006

Endomyocardial biopsy is the gold standard survey for cardiac graft rejection. Signal-averaged electrocardiography (SAECG) identifies slowly conducting, diseased myocardium. We sought to determine whether SAECG is a sensitive, noninvasive transplant surveillance method in the young.Ninety-four SAECGs recorded prior to biopsy in 20 young transplant (OHT) patients and those from 15 healthy age-matched controls (CTL) were analyzed. In the OHT group, 56 no-rejection (NOREJ) (ISHLT grades 0 or 1 A) and 37 acute rejection (REJ) (ISHLT grades IB, 2, and 3A) SAECGs were compared, SAECGs were filtered at 40-255 Hz. Total QRS duration (QRSd), duration of terminal low amplitude of QRS under 40 microV (LAS), and root mean square amplitude of terminal 40 msec of QRS (RMS40) were compared.SAECGs were significantly different in CTL vs NOREJ but not in NOREJ vs REJ: QRSd, 81.7 +/- 8, 107.2 +/- 18.4, and 112.3 +/- 21.6 msec, respectively; LAS, (18 +/- 5.8, 23.6 +/- 10.7, and 27 +/- 14.8 msec, respectively; and RMS40, (169.3 +/- 100.4, 68 +/- 48.8, and 57.5 +/- 45.6 microV, respectively. Children following OHT exhibited significant differences in the SAECG compared to controls. Differences between the NOREJ and REJ groups were negligible. Therefore, SAECG may not be effective in detecting OHT rejection in the young.

Duke Scholars

Published In

Pediatr Cardiol

DOI

ISSN

0172-0643

Publication Date

2006

Volume

27

Issue

5

Start / End Page

589 / 593

Location

United States

Related Subject Headings

  • Transplantation, Homologous
  • Severity of Illness Index
  • Reproducibility of Results
  • Male
  • Humans
  • Heart Transplantation
  • Heart Failure
  • Graft Rejection
  • Follow-Up Studies
  • Female
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Horenstein, M. S., Idriss, S. F., Hamilton, R. M., Kanter, R. J., Webster, P. A., & Karpawich, P. P. (2006). Efficacy of signal-averaged electrocardiography in the young orthotopic heart transplant patient to detect allograft rejection. Pediatr Cardiol, 27(5), 589–593. https://doi.org/10.1007/s00246-005-1155-5
Horenstein, M. S., S. F. Idriss, R. M. Hamilton, R. J. Kanter, P. A. Webster, and P. P. Karpawich. “Efficacy of signal-averaged electrocardiography in the young orthotopic heart transplant patient to detect allograft rejection.Pediatr Cardiol 27, no. 5 (2006): 589–93. https://doi.org/10.1007/s00246-005-1155-5.
Horenstein MS, Idriss SF, Hamilton RM, Kanter RJ, Webster PA, Karpawich PP. Efficacy of signal-averaged electrocardiography in the young orthotopic heart transplant patient to detect allograft rejection. Pediatr Cardiol. 2006;27(5):589–93.
Horenstein, M. S., et al. “Efficacy of signal-averaged electrocardiography in the young orthotopic heart transplant patient to detect allograft rejection.Pediatr Cardiol, vol. 27, no. 5, 2006, pp. 589–93. Pubmed, doi:10.1007/s00246-005-1155-5.
Horenstein MS, Idriss SF, Hamilton RM, Kanter RJ, Webster PA, Karpawich PP. Efficacy of signal-averaged electrocardiography in the young orthotopic heart transplant patient to detect allograft rejection. Pediatr Cardiol. 2006;27(5):589–593.
Journal cover image

Published In

Pediatr Cardiol

DOI

ISSN

0172-0643

Publication Date

2006

Volume

27

Issue

5

Start / End Page

589 / 593

Location

United States

Related Subject Headings

  • Transplantation, Homologous
  • Severity of Illness Index
  • Reproducibility of Results
  • Male
  • Humans
  • Heart Transplantation
  • Heart Failure
  • Graft Rejection
  • Follow-Up Studies
  • Female