Skip to main content

Quantitative Evaluation of Half-Cone-Beam Scan Paths in Triple-Camera Brain SPECT.

Publication ,  Journal Article
Ter-Antonyan, R; Jaszczak, RJ; Bowsher, JE; Greer, KL; Metzler, SD
Published in: IEEE Trans Nucl Sci
October 1, 2008

In this study related to human brain SPECT imaging, simulation of half-cone-beam (HCB) collimation with different scan paths is performed and compared with simulated fan-beam and parallel-hole circular orbit acquisitions of disk-phantom projection data. Acquisition types are quantitatively evaluated based on the photon detection efficiency, the root-mean-squared error, contrast and signal-to-noise ratio measurements of the reconstructed images. We demonstrate that a triple-camera SPECT system with half-cone-beam collimators and circle-and-helix scan paths can offer up to a 26% efficiency increase over fan-beam, and up to a 128% increase over parallel-hole collimators for equal spatial resolutions, and display no visible axial sampling artifacts in reconstructed disk-phantom images. In addition, we perform qualitative experimental evaluation of triple-HCB circle-and-helix acquisition using a Hoffman 3D brain phantom. Reconstructed brain phantom images show improved quality due to reduced noise and no apparent sampling artifacts. Triple-HCB circle-and-helix SPECT has a potential for improved brain imaging, producing higher image quality with a smaller reconstruction error and better lesion detectability due to increased efficiency for equal spatial resolution compared to conventional fan-beam and parallel-hole SPECT.

Duke Scholars

Published In

IEEE Trans Nucl Sci

DOI

ISSN

0018-9499

Publication Date

October 1, 2008

Volume

55

Issue

5

Start / End Page

2518 / 2526

Location

United States

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Ter-Antonyan, R., Jaszczak, R. J., Bowsher, J. E., Greer, K. L., & Metzler, S. D. (2008). Quantitative Evaluation of Half-Cone-Beam Scan Paths in Triple-Camera Brain SPECT. IEEE Trans Nucl Sci, 55(5), 2518–2526. https://doi.org/10.1109/TNS.2008.2003255
Ter-Antonyan, Ruben, Ronald J. Jaszczak, James E. Bowsher, Kim L. Greer, and Scott D. Metzler. “Quantitative Evaluation of Half-Cone-Beam Scan Paths in Triple-Camera Brain SPECT.IEEE Trans Nucl Sci 55, no. 5 (October 1, 2008): 2518–26. https://doi.org/10.1109/TNS.2008.2003255.
Ter-Antonyan R, Jaszczak RJ, Bowsher JE, Greer KL, Metzler SD. Quantitative Evaluation of Half-Cone-Beam Scan Paths in Triple-Camera Brain SPECT. IEEE Trans Nucl Sci. 2008 Oct 1;55(5):2518–26.
Ter-Antonyan, Ruben, et al. “Quantitative Evaluation of Half-Cone-Beam Scan Paths in Triple-Camera Brain SPECT.IEEE Trans Nucl Sci, vol. 55, no. 5, Oct. 2008, pp. 2518–26. Pubmed, doi:10.1109/TNS.2008.2003255.
Ter-Antonyan R, Jaszczak RJ, Bowsher JE, Greer KL, Metzler SD. Quantitative Evaluation of Half-Cone-Beam Scan Paths in Triple-Camera Brain SPECT. IEEE Trans Nucl Sci. 2008 Oct 1;55(5):2518–2526.

Published In

IEEE Trans Nucl Sci

DOI

ISSN

0018-9499

Publication Date

October 1, 2008

Volume

55

Issue

5

Start / End Page

2518 / 2526

Location

United States

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics