Renal shielding and dosimetry for patients with severe systemic sclerosis receiving immunoablation with total body irradiation in the scleroderma: cyclophosphamide or transplantation trial.

Publication ,  Journal Article
Craciunescu, OI; Steffey, BA; Kelsey, CR; Larrier, NA; Paarz-Largay, CJ; Prosnitz, RG; Chao, N; Chute, J; Gasparetto, C; Horwitz, M; Long, G ...
Published in: Int J Radiat Oncol Biol Phys
March 15, 2011

PURPOSE: To describe renal shielding techniques and dosimetry in delivering total body irradiation (TBI) to patients with severe systemic sclerosis (SSc) enrolled in a hematopoietic stem cell transplant protocol. METHODS AND MATERIALS: The Scleroderma: Cyclophosphamide or Transplantation (SCOT) protocol uses a lymphoablative preparative regimen including 800 cGy TBI delivered in two 200-cGy fractions twice a day before CD34(+) selected autologous hematopoietic stem cell transplantation. Lung and kidney doses are limited to 200 cGy to protect organs damaged by SSc. Kidney block proximity to the spinal cord was investigated, and guidelines were developed for acceptable lumbar area TBI dosing. Information about kidney size and the organ shifts from supine to standing positions were recorded using diagnostic ultrasound (US). Minimum distance between the kidney blocks (dkB) and the lumbar spine region dose was recorded, and in vivo dosimetry was performed at several locations to determine the radiation doses delivered. RESULTS: Eleven patients were treated at our center with an anteroposterior (AP)/posteroanterior (PA) TBI technique. A 10% to 20% dose inhomogeneity in the lumbar spine region was achieved with a minimum kidney block separation of 4 to 5 cm. The average lumbar spine dose was 179.6 ± 18.1 cGy, with an average dkB of 5.0 ± 1.0 cm. Kidney block shield design was accomplished using a combination of US and noncontrast computerized tomography (CT) or CT imaging alone. The renal US revealed a wide range of kidney displacement from upright to supine positions. Overall, the average in vivo dose for the kidney prescription point was 193.4 ± 5.1 cGy. CONCLUSIONS: The dose to the kidneys can be attenuated while maintaining a 10% to 20% dose inhomogeneity in the lumbar spine area. Kidneys were localized more accurately using both US and CT imaging. With this technique, renal function has been preserved, and the study continues to enroll patients.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Int J Radiat Oncol Biol Phys

DOI

EISSN

1879-355X

Publication Date

March 15, 2011

Volume

79

Issue

4

Start / End Page

1248 / 1255

Location

United States

Related Subject Headings

  • Whole-Body Irradiation
  • Ultrasonography
  • Transplantation Conditioning
  • Supine Position
  • Scleroderma, Systemic
  • Radiotherapy Planning, Computer-Assisted
  • Radiography
  • Radiation Protection
  • Radiation Injuries
  • Patient Positioning
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Craciunescu, O. I., Steffey, B. A., Kelsey, C. R., Larrier, N. A., Paarz-Largay, C. J., Prosnitz, R. G., … Sullivan, K. M. (2011). Renal shielding and dosimetry for patients with severe systemic sclerosis receiving immunoablation with total body irradiation in the scleroderma: cyclophosphamide or transplantation trial. Int J Radiat Oncol Biol Phys, 79(4), 1248–1255. https://doi.org/10.1016/j.ijrobp.2010.05.036
Craciunescu, Oana I., Beverly A. Steffey, Chris R. Kelsey, Nicole A. Larrier, Cathy J. Paarz-Largay, Robert G. Prosnitz, Nelson Chao, et al. “Renal shielding and dosimetry for patients with severe systemic sclerosis receiving immunoablation with total body irradiation in the scleroderma: cyclophosphamide or transplantation trial.Int J Radiat Oncol Biol Phys 79, no. 4 (March 15, 2011): 1248–55. https://doi.org/10.1016/j.ijrobp.2010.05.036.
Craciunescu OI, Steffey BA, Kelsey CR, Larrier NA, Paarz-Largay CJ, Prosnitz RG, et al. Renal shielding and dosimetry for patients with severe systemic sclerosis receiving immunoablation with total body irradiation in the scleroderma: cyclophosphamide or transplantation trial. Int J Radiat Oncol Biol Phys. 2011 Mar 15;79(4):1248–55.
Craciunescu, Oana I., et al. “Renal shielding and dosimetry for patients with severe systemic sclerosis receiving immunoablation with total body irradiation in the scleroderma: cyclophosphamide or transplantation trial.Int J Radiat Oncol Biol Phys, vol. 79, no. 4, Mar. 2011, pp. 1248–55. Pubmed, doi:10.1016/j.ijrobp.2010.05.036.
Craciunescu OI, Steffey BA, Kelsey CR, Larrier NA, Paarz-Largay CJ, Prosnitz RG, Chao N, Chute J, Gasparetto C, Horwitz M, Long G, Rizzieri D, Sullivan KM. Renal shielding and dosimetry for patients with severe systemic sclerosis receiving immunoablation with total body irradiation in the scleroderma: cyclophosphamide or transplantation trial. Int J Radiat Oncol Biol Phys. 2011 Mar 15;79(4):1248–1255.
Journal cover image

Published In

Int J Radiat Oncol Biol Phys

DOI

EISSN

1879-355X

Publication Date

March 15, 2011

Volume

79

Issue

4

Start / End Page

1248 / 1255

Location

United States

Related Subject Headings

  • Whole-Body Irradiation
  • Ultrasonography
  • Transplantation Conditioning
  • Supine Position
  • Scleroderma, Systemic
  • Radiotherapy Planning, Computer-Assisted
  • Radiography
  • Radiation Protection
  • Radiation Injuries
  • Patient Positioning