A visual assay to monitor purification of cell surface antigens reacting with monoclonal antibodies.

Publication ,  Journal Article
Eisenbarth, GS; Rankin, RB; Haynes, BF; Fauci, AS
Published in: J Immunol Methods
1980

We have developed a visual microtiter assay to detect solubilized cell-surface antigens which react with monoclonal antibodies. The assay depends on the ability of adsorbed monoclonal antibody to bind target cells to microtiter V wells, and the inhibition of binding by antigen. We have used this assay to follow a 600-fold purification of the human lymphocyte differentiation antigen 3A1 extracted from HSB-2 cells. Antigen 3A1 is a glycoprotein with a molecular weight of approximately 40,000 daltons.

Duke Scholars

Published In

J Immunol Methods

DOI

ISSN

0022-1759

Publication Date

1980

Volume

39

Issue

4

Start / End Page

387 / 392

Location

Netherlands

Related Subject Headings

  • Immunology
  • Electrophoresis, Polyacrylamide Gel
  • Clone Cells
  • Binding Sites, Antibody
  • Antigens, Surface
  • Antigen-Antibody Reactions
  • Antibodies
  • Adsorption
  • 3204 Immunology
  • 3101 Biochemistry and cell biology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Eisenbarth, G. S., Rankin, R. B., Haynes, B. F., & Fauci, A. S. (1980). A visual assay to monitor purification of cell surface antigens reacting with monoclonal antibodies. J Immunol Methods, 39(4), 387–392. https://doi.org/10.1016/0022-1759(80)90239-2
Eisenbarth, G. S., R. B. Rankin, B. F. Haynes, and A. S. Fauci. “A visual assay to monitor purification of cell surface antigens reacting with monoclonal antibodies.J Immunol Methods 39, no. 4 (1980): 387–92. https://doi.org/10.1016/0022-1759(80)90239-2.
Eisenbarth GS, Rankin RB, Haynes BF, Fauci AS. A visual assay to monitor purification of cell surface antigens reacting with monoclonal antibodies. J Immunol Methods. 1980;39(4):387–92.
Eisenbarth, G. S., et al. “A visual assay to monitor purification of cell surface antigens reacting with monoclonal antibodies.J Immunol Methods, vol. 39, no. 4, 1980, pp. 387–92. Pubmed, doi:10.1016/0022-1759(80)90239-2.
Eisenbarth GS, Rankin RB, Haynes BF, Fauci AS. A visual assay to monitor purification of cell surface antigens reacting with monoclonal antibodies. J Immunol Methods. 1980;39(4):387–392.
Journal cover image

Published In

J Immunol Methods

DOI

ISSN

0022-1759

Publication Date

1980

Volume

39

Issue

4

Start / End Page

387 / 392

Location

Netherlands

Related Subject Headings

  • Immunology
  • Electrophoresis, Polyacrylamide Gel
  • Clone Cells
  • Binding Sites, Antibody
  • Antigens, Surface
  • Antigen-Antibody Reactions
  • Antibodies
  • Adsorption
  • 3204 Immunology
  • 3101 Biochemistry and cell biology