Nebulizer delivery of micafungin aerosols.

Publication ,  Journal Article
Alexander, BD; Winkler, TP; Shi, S; Ashley, ESD; Hickey, AJ
Published in: Pharmacotherapy
January 2011

STUDY OBJECTIVES: To determine the optimal nebulization system for aerosolizing micafungin and to further assess the physiochemical properties of aerosolized micafungin. DESIGN: In vitro experiment. SETTING: University research center. NEBULIZERS: Pari LC Star, Hudson Updraft, Small Volume Nebulizer, and Aeroclipse II. MEASUREMENTS AND MAIN RESULTS: Using a commercially available cascade impactor, the four nebulizers were tested for their ability to deliver micafungin to the lungs. Mass median aerodynamic diameter (MMAD) and fine particle fraction (FPF) percent less than 3.3 μm (FPF(3.3)) and less than 5.8 μm (FPF(5.8)) were determined during two sampling periods for each of three trials of all nebulizers. The mean ± standard error of the mean MMAD for the nebulizers ranged from 1.93 ± 0.09 to 2.49 ± 0.25 μm; FPF(3.3) and FPF(5.8) were approximately 50% and 90%, respectively, for all nebulizers. CONCLUSION: Although all nebulizers appeared acceptable to deliver micafungin to the lungs, the Pari LC Star had the smallest MMAD and highest FPF(3.3) and FPF(5.8). These properties of the Pari LC Star should result in greater delivery of the aerosol to the lungs. Additional research on pulmonary delivery and clinical tolerability is warranted.

Duke Scholars

Published In

Pharmacotherapy

DOI

EISSN

1875-9114

Publication Date

January 2011

Volume

31

Issue

1

Start / End Page

52 / 57

Location

United States

Related Subject Headings

  • Pharmacology & Pharmacy
  • Particle Size
  • Nebulizers and Vaporizers
  • Micafungin
  • Lipopeptides
  • Humans
  • Echinocandins
  • Drug Delivery Systems
  • Antifungal Agents
  • Aerosols
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Alexander, B. D., Winkler, T. P., Shi, S., Ashley, E. S. D., & Hickey, A. J. (2011). Nebulizer delivery of micafungin aerosols. Pharmacotherapy, 31(1), 52–57. https://doi.org/10.1592/phco.31.1.52
Alexander, Barbara D., Thomas P. Winkler, Shuai Shi, Elizabeth S Dodds Ashley, and Anthony J. Hickey. “Nebulizer delivery of micafungin aerosols.Pharmacotherapy 31, no. 1 (January 2011): 52–57. https://doi.org/10.1592/phco.31.1.52.
Alexander BD, Winkler TP, Shi S, Ashley ESD, Hickey AJ. Nebulizer delivery of micafungin aerosols. Pharmacotherapy. 2011 Jan;31(1):52–7.
Alexander, Barbara D., et al. “Nebulizer delivery of micafungin aerosols.Pharmacotherapy, vol. 31, no. 1, Jan. 2011, pp. 52–57. Pubmed, doi:10.1592/phco.31.1.52.
Alexander BD, Winkler TP, Shi S, Ashley ESD, Hickey AJ. Nebulizer delivery of micafungin aerosols. Pharmacotherapy. 2011 Jan;31(1):52–57.
Journal cover image

Published In

Pharmacotherapy

DOI

EISSN

1875-9114

Publication Date

January 2011

Volume

31

Issue

1

Start / End Page

52 / 57

Location

United States

Related Subject Headings

  • Pharmacology & Pharmacy
  • Particle Size
  • Nebulizers and Vaporizers
  • Micafungin
  • Lipopeptides
  • Humans
  • Echinocandins
  • Drug Delivery Systems
  • Antifungal Agents
  • Aerosols