Cost-effectiveness of defibrillator therapy or amiodarone in chronic stable heart failure: results from the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT).

Published

Journal Article

BACKGROUND: In the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), implantable cardioverter-defibrillator (ICD) therapy significantly reduced all-cause mortality rates compared with medical therapy alone in patients with stable, moderately symptomatic heart failure, whereas amiodarone had no benefit on mortality rates. We examined long-term economic implications of these results. METHODS AND RESULTS: Medical costs were estimated by using hospital billing data and the Medicare Fee Schedule. Our base case cost-effectiveness analysis used empirical clinical and cost data to estimate the lifetime incremental cost of saving an extra life-year with ICD therapy relative to medical therapy alone. At 5 years, the amiodarone arm had a survival rate equivalent to that of the placebo arm and higher costs than the placebo arm. For ICD relative to medical therapy alone, the base case lifetime cost-effectiveness and cost-utility ratios (discounted at 3%) were dollar 38,389 per life-year saved (LYS) and dollar 41,530 per quality-adjusted LYS, respectively. A cost-effectiveness ratio < dollar 100,000 was obtained in 99% of 1000 bootstrap repetitions. The cost-effectiveness ratio was sensitive to the amount of extrapolation beyond the empirical 5-year trial data: dollar 127,503 per LYS at 5 years, dollar 88,657 per LYS at 8 years, and dollar 58,510 per LYS at 12 years. Because of a significant interaction between ICD treatment and New York Heart Association class, the cost-effectiveness ratio was dollar 29,872 per LYS for class II, whereas there was incremental cost but no incremental benefit in class III. CONCLUSIONS: Prophylactic use of single-lead, shock-only ICD therapy is economically attractive in patients with stable, moderately symptomatic heart failure with an ejection fraction < or = 35%, particularly those in NYHA class II, as long as the benefits of ICD therapy observed in the SCD-HeFT persist for at least 8 years.

Full Text

Duke Authors

Cited Authors

  • Mark, DB; Nelson, CL; Anstrom, KJ; Al-Khatib, SM; Tsiatis, AA; Cowper, PA; Clapp-Channing, NE; Davidson-Ray, L; Poole, JE; Johnson, G; Anderson, J; Lee, KL; Bardy, GH; SCD-HeFT Investigators,

Published Date

  • July 11, 2006

Published In

Volume / Issue

  • 114 / 2

Start / End Page

  • 135 - 142

PubMed ID

  • 16818817

Pubmed Central ID

  • 16818817

Electronic International Standard Serial Number (EISSN)

  • 1524-4539

Digital Object Identifier (DOI)

  • 10.1161/CIRCULATIONAHA.105.581884

Language

  • eng

Conference Location

  • United States