Realistic reference adult and paediatric phantom series for internal and external dosimetry.
Journal Article (Journal Article)
A new generation of realistic, image-based anthropomorphic phantoms has been developed based on the reference masses and organ definitions given in the International Commission on Radiological Protection Publication 89. Specific absorbed fractions for internal radiation sources have been calculated for photon and electron sources for many body organs. Values are similar to those from the previous generation of 'stylized' (mathematical equation-based) models, but some differences are seen, particularly at low particle or photon energies, due to the more realistic organ geometries, with organs generally being closer together, and with some touching and overlapping. Extension of this work, to use these phantoms in Monte Carlo radiation transport simulation codes with external radiation sources, is an important area of investigation that should be undertaken.
Full Text
Duke Authors
Cited Authors
- Stabin, MG; Emmons, MA; Segars, WP; Fernald, MJ
Published Date
- March 2012
Published In
Volume / Issue
- 149 / 1
Start / End Page
- 56 - 59
PubMed ID
- 22128359
Pubmed Central ID
- PMC3303490
Electronic International Standard Serial Number (EISSN)
- 1742-3406
Digital Object Identifier (DOI)
- 10.1093/rpd/ncr383
Language
- eng
Conference Location
- England