Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic management.

Publication ,  Journal Article
Chen, G; Chung, E; Meng, L; Alexander, B; Vu, T; Rinehart, J; Cannesson, M
Published in: J Clin Monit Comput
April 2012

The Nexfin device allows for non-invasive beat-to-beat blood pressure monitoring (BP(NXF)). Perioperative hypotension and hypertension have been shown to be associated with poor clinical outcomes. The goal of the present study was to assess the ability of this device to decrease the duration of significant intraoperative hypo- or hypertension compared to standard BP monitoring by cuff (BP(CUFF)). We studied25 patients (ASA I-III) undergoing either abdominal or orthopedic surgery. BP(CUFF) was monitored every 5 min from the introduction of anesthesia, while BP(NXF) was monitored continuously on the opposite arm. When systolic BP(NXF) (SBP(NXF)) decreased or increased more than 20% relative to baseline SBP(NXF), a standard BP(CUFF) measurement was taken to compare values. In addition, the time interval between the 20% change in SBP(NXF) and the next scheduled standard SBP(CUFF) measurement was recorded for each event. The mean length of surgery was 3.0 ± 0.3 h. Patients presented with 11 ± 4 episodes of hypotension and 12 ± 4 episodes of hypertension during the surgery. If BP(CUFF) had been used, this would have resulted in 21 ± 7 min of hypotension and 20 ± 10 min of hypertension. If hemodynamic changes seen by SBP(NXF) were appropriately treated, an average of 7 ± 1 min/h of hypotension time, 7 ± 2 min/h of hypertension time and 14 ± 3 min per hour of hypo- or hypertension time may have been identified. The Nexfin BP has the potential to decrease the time of hypotension and hypertension compared to conventional intermittent BP(CUFF) monitoring. Therefore, this device has the potential to positively impact clinical outcomes.

Published In

J Clin Monit Comput

DOI

EISSN

1573-2614

Publication Date

April 2012

Volume

26

Issue

2

Start / End Page

133 / 140

Location

Netherlands

Related Subject Headings

  • Time Factors
  • Orthopedics
  • Monitoring, Physiologic
  • Monitoring, Intraoperative
  • Middle Aged
  • Male
  • Hypotension
  • Hypertension
  • Humans
  • Hemodynamics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chen, G., Chung, E., Meng, L., Alexander, B., Vu, T., Rinehart, J., & Cannesson, M. (2012). Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic management. J Clin Monit Comput, 26(2), 133–140. https://doi.org/10.1007/s10877-012-9344-2
Chen, Guo, Elena Chung, Lingzhong Meng, Brenton Alexander, Trung Vu, Joseph Rinehart, and Maxime Cannesson. “Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic management.J Clin Monit Comput 26, no. 2 (April 2012): 133–40. https://doi.org/10.1007/s10877-012-9344-2.
Chen G, Chung E, Meng L, Alexander B, Vu T, Rinehart J, et al. Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic management. J Clin Monit Comput. 2012 Apr;26(2):133–40.
Chen, Guo, et al. “Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic management.J Clin Monit Comput, vol. 26, no. 2, Apr. 2012, pp. 133–40. Pubmed, doi:10.1007/s10877-012-9344-2.
Chen G, Chung E, Meng L, Alexander B, Vu T, Rinehart J, Cannesson M. Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic management. J Clin Monit Comput. 2012 Apr;26(2):133–140.
Journal cover image

Published In

J Clin Monit Comput

DOI

EISSN

1573-2614

Publication Date

April 2012

Volume

26

Issue

2

Start / End Page

133 / 140

Location

Netherlands

Related Subject Headings

  • Time Factors
  • Orthopedics
  • Monitoring, Physiologic
  • Monitoring, Intraoperative
  • Middle Aged
  • Male
  • Hypotension
  • Hypertension
  • Humans
  • Hemodynamics