Effects of stimulation parameters and electrode location on thresholds for epidural stimulation of cat motor cortex.

Published

Journal Article

Epidural electrical stimulation (ECS) of the motor cortex is a developing therapy for neurological disorders. Both placement and programming of ECS systems may affect the therapeutic outcome, but the treatment parameters that will maximize therapeutic outcomes and minimize side effects are not known. We delivered ECS to the motor cortex of anesthetized cats and investigated the effects of electrode placement and stimulation parameters on thresholds for evoking motor responses in the contralateral forelimb. Thresholds were inversely related to stimulation frequency and the number of pulses per stimulus train. Thresholds were lower over the forelimb representation in motor cortex (primary site) than surrounding sites (secondary sites), and thresholds at sites <4 mm away from the primary site were significantly lower than at sites >4 mm away. Electrode location and montage influenced the effects of polarity on thresholds: monopolar anodic and cathodic thresholds were not significantly different over the primary site, cathodic thresholds were significantly lower than anodic thresholds over secondary sites and bipolar thresholds were significantly lower with the anode over the primary site than with the cathode over the primary site. A majority of bipolar thresholds were either between or equal to the respective monopolar thresholds, but several bipolar thresholds were greater than or less than the monopolar thresholds of both the anode and cathode. During bipolar stimulation, thresholds were influenced by both electric field superposition and indirect, synaptically mediated interactions. These results demonstrate the influence of stimulation parameters and electrode location during cortical stimulation, and these effects should be considered during the programming of systems for therapeutic cortical stimulation.

Full Text

Duke Authors

Cited Authors

  • Wongsarnpigoon, A; Grill, WM

Published Date

  • December 2011

Published In

Volume / Issue

  • 8 / 6

Start / End Page

  • 066016 -

PubMed ID

  • 22086218

Pubmed Central ID

  • 22086218

Electronic International Standard Serial Number (EISSN)

  • 1741-2552

International Standard Serial Number (ISSN)

  • 1741-2560

Digital Object Identifier (DOI)

  • 10.1088/1741-2560/8/6/066016

Language

  • eng