Skip to main content
Journal cover image

Evaluation of the reproducibility of lung motion probability distribution function (PDF) using dynamic MRI.

Publication ,  Journal Article
Cai, J; Read, PW; Altes, TA; Molloy, JA; Brookeman, JR; Sheng, K
Published in: Phys Med Biol
January 21, 2007

Treatment planning based on probability distribution function (PDF) of patient geometries has been shown a potential off-line strategy to incorporate organ motion, but the application of such approach highly depends upon the reproducibility of the PDF. In this paper, we investigated the dependences of the PDF reproducibility on the imaging acquisition parameters, specifically the scan time and the frame rate. Three healthy subjects underwent a continuous 5 min magnetic resonance (MR) scan in the sagittal plane with a frame rate of approximately 10 f s-1, and the experiments were repeated with an interval of 2 to 3 weeks. A total of nine pulmonary vessels from different lung regions (upper, middle and lower) were tracked and the dependences of their displacement PDF reproducibility were evaluated as a function of scan time and frame rate. As results, the PDF reproducibility error decreased with prolonged scans and appeared to approach equilibrium state in subjects 2 and 3 within the 5 min scan. The PDF accuracy increased in the power function with the increase of frame rate; however, the PDF reproducibility showed less sensitivity to frame rate presumably due to the randomness of breathing which dominates the effects. As the key component of the PDF-based treatment planning, the reproducibility of the PDF affects the dosimetric accuracy substantially. This study provides a reference for acquiring MR-based PDF of structures in the lung.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Phys Med Biol

DOI

ISSN

0031-9155

Publication Date

January 21, 2007

Volume

52

Issue

2

Start / End Page

365 / 373

Location

England

Related Subject Headings

  • Whole Body Imaging
  • Time Factors
  • Respiratory Physiological Phenomena
  • Respiration
  • Reproducibility of Results
  • Radiometry
  • Probability
  • Nuclear Medicine & Medical Imaging
  • Movement
  • Models, Statistical
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Cai, J., Read, P. W., Altes, T. A., Molloy, J. A., Brookeman, J. R., & Sheng, K. (2007). Evaluation of the reproducibility of lung motion probability distribution function (PDF) using dynamic MRI. Phys Med Biol, 52(2), 365–373. https://doi.org/10.1088/0031-9155/52/2/004
Cai, Jing, Paul W. Read, Talissa A. Altes, Janelle A. Molloy, James R. Brookeman, and Ke Sheng. “Evaluation of the reproducibility of lung motion probability distribution function (PDF) using dynamic MRI.Phys Med Biol 52, no. 2 (January 21, 2007): 365–73. https://doi.org/10.1088/0031-9155/52/2/004.
Cai J, Read PW, Altes TA, Molloy JA, Brookeman JR, Sheng K. Evaluation of the reproducibility of lung motion probability distribution function (PDF) using dynamic MRI. Phys Med Biol. 2007 Jan 21;52(2):365–73.
Cai, Jing, et al. “Evaluation of the reproducibility of lung motion probability distribution function (PDF) using dynamic MRI.Phys Med Biol, vol. 52, no. 2, Jan. 2007, pp. 365–73. Pubmed, doi:10.1088/0031-9155/52/2/004.
Cai J, Read PW, Altes TA, Molloy JA, Brookeman JR, Sheng K. Evaluation of the reproducibility of lung motion probability distribution function (PDF) using dynamic MRI. Phys Med Biol. 2007 Jan 21;52(2):365–373.
Journal cover image

Published In

Phys Med Biol

DOI

ISSN

0031-9155

Publication Date

January 21, 2007

Volume

52

Issue

2

Start / End Page

365 / 373

Location

England

Related Subject Headings

  • Whole Body Imaging
  • Time Factors
  • Respiratory Physiological Phenomena
  • Respiration
  • Reproducibility of Results
  • Radiometry
  • Probability
  • Nuclear Medicine & Medical Imaging
  • Movement
  • Models, Statistical