Skip to main content
Journal cover image

A new modality in nonstress testing: evaluation of beat-to-beat fetal heart rate variability.

Publication ,  Journal Article
Lauersen, NH; Wilson, KH; Bilek, A; Rao, VS; Kurkulos, M
Published in: Am J Obstet Gynecol
November 1, 1981

Fetal monitoring equipment that provided accurate external measurement of the interval between each fetal heartbeat permitted the evaluation of beat-to-beat fetal heart rate (FHR) variability as part of routine nonstress testing. Nonstress tests (NSTs) were performed on 350 high-risk patients over a 12-month period. The beat-to-beat FHR variability and the reactivity of the last NST within 7 days of labor were analyzed in relation to the appearance of fetal distress during labor as indicated by late decelerations. Beat-to-beat FHR variability combined with nonstress testing was more predictive of subsequent fetal distress than nonstress testing alone. In all instances, complete loss of beat-to-beat FHR was followed by fetal distress during labor. Fetal distress was present in only 39% of labors following nonreactive NSTs. The inclusion of beat-to-beat FHR variability in nonstress testing can significantly aid in the detection of fetal compromise.

Duke Scholars

Published In

Am J Obstet Gynecol

DOI

ISSN

0002-9378

Publication Date

November 1, 1981

Volume

141

Issue

5

Start / End Page

521 / 526

Location

United States

Related Subject Headings

  • Risk
  • Pregnancy Complications
  • Pregnancy
  • Obstetrics & Reproductive Medicine
  • Movement
  • Humans
  • Heart Rate
  • Fetal Monitoring
  • Fetal Heart
  • Fetal Distress
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Lauersen, N. H., Wilson, K. H., Bilek, A., Rao, V. S., & Kurkulos, M. (1981). A new modality in nonstress testing: evaluation of beat-to-beat fetal heart rate variability. Am J Obstet Gynecol, 141(5), 521–526. https://doi.org/10.1016/s0002-9378(15)33272-5
Lauersen, N. H., K. H. Wilson, A. Bilek, V. S. Rao, and M. Kurkulos. “A new modality in nonstress testing: evaluation of beat-to-beat fetal heart rate variability.Am J Obstet Gynecol 141, no. 5 (November 1, 1981): 521–26. https://doi.org/10.1016/s0002-9378(15)33272-5.
Lauersen NH, Wilson KH, Bilek A, Rao VS, Kurkulos M. A new modality in nonstress testing: evaluation of beat-to-beat fetal heart rate variability. Am J Obstet Gynecol. 1981 Nov 1;141(5):521–6.
Lauersen, N. H., et al. “A new modality in nonstress testing: evaluation of beat-to-beat fetal heart rate variability.Am J Obstet Gynecol, vol. 141, no. 5, Nov. 1981, pp. 521–26. Pubmed, doi:10.1016/s0002-9378(15)33272-5.
Lauersen NH, Wilson KH, Bilek A, Rao VS, Kurkulos M. A new modality in nonstress testing: evaluation of beat-to-beat fetal heart rate variability. Am J Obstet Gynecol. 1981 Nov 1;141(5):521–526.
Journal cover image

Published In

Am J Obstet Gynecol

DOI

ISSN

0002-9378

Publication Date

November 1, 1981

Volume

141

Issue

5

Start / End Page

521 / 526

Location

United States

Related Subject Headings

  • Risk
  • Pregnancy Complications
  • Pregnancy
  • Obstetrics & Reproductive Medicine
  • Movement
  • Humans
  • Heart Rate
  • Fetal Monitoring
  • Fetal Heart
  • Fetal Distress