Implantable cardioverter-defibrillators in patients hospitalized for heart failure with chronically reduced left ventricular ejection fraction.

Published

Journal Article

The aim of this study was to investigate the association between implantable cardioverter-defibrillator (ICD) status at the time of hospitalization for worsening heart failure (HF) with postdischarge events in patients with reduced left ventricular ejection fraction. We conducted an analysis of 4133 patients hospitalized for HF with left ventricular ejection fraction 40% or less in EVEREST. The final analysis included patients without an electrophysiological device (n = 3102) and those with an ICD (n = 600) at the time of enrollment. During a median follow-up of 300 days, all-cause mortality was 22.9% in the no device group and 35.2% in the ICD group (hazard ratio [HR], 1.62; 95% confidence interval [CI], 1.39-1.89). Rehospitalization for HF was 27.0% in the no device group and 46.8% in the ICD group (HR, 2.20; 95% CI, 1.92-2.52). After adjustment for multiple variables, the rates for all-cause mortality were similar (HR, 1.01; 95% CI, 0.83-1.22), but the ICD group had elevated rates of HF hospitalizations compared with the no device group (HR, 1.35; 95% CI, 1.14-1.60). In patients with reduced left ventricular ejection fraction, an ICD at presentation for hospitalization for worsening HF was associated with similar rates of death but higher rates of rehospitalization for HF. Given our findings, further studies should investigate optimization of care in patients already implanted with an ICD as well as the role of ICD implantation during or soon after hospitalization for HF in patients not yet implanted.

Full Text

Duke Authors

Cited Authors

  • Wang, NC; Piccini, JP; Konstam, MA; Maggioni, AP; Traver, B; Swedberg, K; Udelson, JE; Zannad, F; Cook, T; O'Connor, CM; Miller, AB; Grinfeld, L; Gheorghiade, M; EVEREST Investigators,

Published Date

  • July 2010

Published In

Volume / Issue

  • 17 / 4

Start / End Page

  • e78 - e87

PubMed ID

  • 20634650

Pubmed Central ID

  • 20634650

Electronic International Standard Serial Number (EISSN)

  • 1536-3686

Digital Object Identifier (DOI)

  • 10.1097/MJT.0b013e3181e70a65

Language

  • eng

Conference Location

  • United States