Automated size-specific CT dose monitoring program: assessing variability in CT dose.

Publication ,  Journal Article
Christianson, O; Li, X; Frush, D; Samei, E
Published in: Med Phys
November 2012

PURPOSE: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. METHODS: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED(adj)). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED(adj) between scanner models and across institutions. RESULTS: No significant difference was found between computer measurements of patient thickness and observer measurements (p = 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED(adj) that differed by up to 44% from effective dose estimates that were not adjusted by patient size. Additionally, considerable differences were noted in ED(adj) distributions between scanners, with scanners employing iterative reconstruction exhibiting significantly lower ED(adj) (range: 9%-64%). Finally, a significant difference (up to 59%) in ED(adj) distributions was observed between institutions, indicating the potential for dose reduction. CONCLUSIONS: The authors developed a robust automated size-specific radiation dose monitoring program for CT. Using this program, significant differences in ED(adj) were observed between scanner models and across institutions. This new dose monitoring program offers a unique tool for improving quality assurance and standardization both within and across institutions.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

November 2012

Volume

39

Issue

11

Start / End Page

7131 / 7139

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Radiation Dosage
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Body Size
  • Automation
  • Algorithms
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Christianson, O., Li, X., Frush, D., & Samei, E. (2012). Automated size-specific CT dose monitoring program: assessing variability in CT dose. Med Phys, 39(11), 7131–7139. https://doi.org/10.1118/1.4761871
Christianson, Olav, Xiang Li, Donald Frush, and Ehsan Samei. “Automated size-specific CT dose monitoring program: assessing variability in CT dose.Med Phys 39, no. 11 (November 2012): 7131–39. https://doi.org/10.1118/1.4761871.
Christianson O, Li X, Frush D, Samei E. Automated size-specific CT dose monitoring program: assessing variability in CT dose. Med Phys. 2012 Nov;39(11):7131–9.
Christianson, Olav, et al. “Automated size-specific CT dose monitoring program: assessing variability in CT dose.Med Phys, vol. 39, no. 11, Nov. 2012, pp. 7131–39. Pubmed, doi:10.1118/1.4761871.
Christianson O, Li X, Frush D, Samei E. Automated size-specific CT dose monitoring program: assessing variability in CT dose. Med Phys. 2012 Nov;39(11):7131–7139.

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

November 2012

Volume

39

Issue

11

Start / End Page

7131 / 7139

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Radiation Dosage
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Body Size
  • Automation
  • Algorithms
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis