Skip to main content

Discrete scintillator coupled mercuric iodide photodetector arrays for breast imaging

Publication ,  Journal Article
Tornai, MP; Patt, BE; Iwanczyk, JS; Levin, CS; Hoffman, ES
Published in: IEEE Nuclear Science Symposium & Medical Imaging Conference
December 1, 1996

Multi-element (4×4) imaging arrays with high resolution collimators, size matched to discrete CsI(Tl) scintillator arrays and mercuric iodide photodetector arrays (HgI2 PDA) are under development as prototypes for larger 16×16 element arrays. The compact nature of the arrays allows detector positioning in proximity to the breast to eliminate activity not in the line-of-sight of the collimator, thus reducing image background. Short collimators, size matched to ≤1.5×1.5 mm2 scintillators show a factor of 2 and 3.4 improvement in spatial resolution and efficiency, respectively, compared to high resolution collimated gamma cameras for the anticipated compressed breast geometries. Monte Carlo simulations, confirmed by measurements, demonstrated that scintillator length played a greater role in efficiency and photofraction for 140 keV gammas than cross sectional area, which affects intrinsic spatial resolution. Simulations also demonstrated that an increase in the ratio of scintillator area to length corresponds to an improvement in light collection. Electronic noise was below 40 e- RMS indicating that detector resolution was not noise limited. The high quantum efficiency and spectral match of prototype unity gain HgI2 PDAs coupled to 1×1×2.5 mm3 and 2×2×4 mm3 CsI(Tl) scintillators demonstrated energy resolutions of 9.4% and 8.8% FWHM at 140 keV, respectively, without the spectral tailing observed in standard high-Z, compound semi-conductor detectors. Line spread function measurements matched the scintillator size and pitch, and small, complex phantoms were easily imaged.

Duke Scholars

Published In

IEEE Nuclear Science Symposium & Medical Imaging Conference

Publication Date

December 1, 1996

Volume

2

Start / End Page

1034 / 1038
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tornai, M. P., Patt, B. E., Iwanczyk, J. S., Levin, C. S., & Hoffman, E. S. (1996). Discrete scintillator coupled mercuric iodide photodetector arrays for breast imaging. IEEE Nuclear Science Symposium & Medical Imaging Conference, 2, 1034–1038.
Tornai, M. P., B. E. Patt, J. S. Iwanczyk, C. S. Levin, and E. S. Hoffman. “Discrete scintillator coupled mercuric iodide photodetector arrays for breast imaging.” IEEE Nuclear Science Symposium & Medical Imaging Conference 2 (December 1, 1996): 1034–38.
Tornai MP, Patt BE, Iwanczyk JS, Levin CS, Hoffman ES. Discrete scintillator coupled mercuric iodide photodetector arrays for breast imaging. IEEE Nuclear Science Symposium & Medical Imaging Conference. 1996 Dec 1;2:1034–8.
Tornai, M. P., et al. “Discrete scintillator coupled mercuric iodide photodetector arrays for breast imaging.” IEEE Nuclear Science Symposium & Medical Imaging Conference, vol. 2, Dec. 1996, pp. 1034–38.
Tornai MP, Patt BE, Iwanczyk JS, Levin CS, Hoffman ES. Discrete scintillator coupled mercuric iodide photodetector arrays for breast imaging. IEEE Nuclear Science Symposium & Medical Imaging Conference. 1996 Dec 1;2:1034–1038.

Published In

IEEE Nuclear Science Symposium & Medical Imaging Conference

Publication Date

December 1, 1996

Volume

2

Start / End Page

1034 / 1038