Radiation synovectomy with 165Dy-FHMA: lymph node uptake and radiation dosimetry calculations.
Journal Article (Journal Article)
The lymph node uptake of 165Dy was measured in 25 patients treated by radiation synovectomy via intra-articular injection of 165Dy-ferric hydroxide macroaggregates (FHMA). An average of 0.12% of the injected dose was found in the inguinal lymph nodes 19h post injection. This results in a lymph node of 16.6 rad (166 mGy), a dose significantly less than that reported following radiation synovectomy with other radiocolloids. Dosimetry calculations for the intra-articular injection of 165Dy-FHMA are provided in the appendix.
Full Text
Duke Authors
Cited Authors
- Zalutsky, MR; Venkatesan, PP; English, RJ; Shortkroff, S; Sledge, CB; Adelstein, SJ
Published Date
- 1986
Published In
Volume / Issue
- 12 / 6
Start / End Page
- 457 - 465
PubMed ID
- 3710708
International Standard Serial Number (ISSN)
- 0047-0740
Digital Object Identifier (DOI)
- 10.1016/s0047-0740(86)80008-0
Language
- eng
Conference Location
- United States