Skip to main content

Optimized radiographic spectra for digital subtraction angiography in the mouse

Publication ,  Conference
De Lin, M; Badea, CT; Johnson, GA
Published in: 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano
December 1, 2004

The availability of genetically altered mouse models of human disease and the increasing use of small animals in basic research have spurred extraordinary interest in new imaging methodologies - particularly magnetic resonance microscopy, microCT, and microPET. To date, very little attention has been given to planar radiographic imaging. Yet there exists enormous potential for this modality given the ease of use and its potential speed. Functional imaging in mouse models can be addressed particularly well through the use of digital subtraction angiography. We describe here a system designed explicitly for digital subtraction angiography in the mouse and the optimization of acquisition parameters required to perform the highest quality functional subtraction angiograms. We focus on optimization of contrast using selective K-edge filters and the optimization of contrast agent though a carefully controlled biological pulse sequence. © 2004 IEEE.

Duke Scholars

Published In

2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano

ISBN

9780780383883

Publication Date

December 1, 2004

Volume

2

Start / End Page

1412 / 1415
 

Citation

APA
Chicago
ICMJE
MLA
NLM
De Lin, M., Badea, C. T., & Johnson, G. A. (2004). Optimized radiographic spectra for digital subtraction angiography in the mouse. In 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano (Vol. 2, pp. 1412–1415).
De Lin, M., C. T. Badea, and G. A. Johnson. “Optimized radiographic spectra for digital subtraction angiography in the mouse.” In 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano, 2:1412–15, 2004.
De Lin M, Badea CT, Johnson GA. Optimized radiographic spectra for digital subtraction angiography in the mouse. In: 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano. 2004. p. 1412–5.
De Lin, M., et al. “Optimized radiographic spectra for digital subtraction angiography in the mouse.” 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano, vol. 2, 2004, pp. 1412–15.
De Lin M, Badea CT, Johnson GA. Optimized radiographic spectra for digital subtraction angiography in the mouse. 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano. 2004. p. 1412–1415.

Published In

2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano

ISBN

9780780383883

Publication Date

December 1, 2004

Volume

2

Start / End Page

1412 / 1415