Skip to main content
Journal cover image

Follow-up recatheterization after balloon aortic valvuloplasty. Mansfield Scientific Aortic Valvuloplasty Registry Investigators.

Publication ,  Journal Article
Bashore, TM; Davidson, CJ
Published in: J Am Coll Cardiol
April 1991

The results of recatheterization were assessed in a select group of 95 patients enrolled in the Mansfield Scientific Aortic Valvuloplasty Registry to determine whether any procedural or patient-related variables at baseline predicted either initial immediate or follow-up (6.2 +/- 3.3 months) results. At the follow-up catheterization, 39 (41%) of the patients were in improved condition and 56 patients (59%) had recurrence of symptoms, allowing for analysis of the effect of the procedure in two symptomatic patient subsets. In the total group the aortic valve area increased initially from 0.56 +/- 0.16 to 0.87 +/- 0.27 cm2 but partial return to the baseline valve area was evident at follow-up (0.63 +/- 0.25 cm2). Similarly, the mean aortic gradient initially decreased from 72 +/- 30 to 35 +/- 16 mm Hg but then increased to 55 +/- 25 mm Hg at follow-up. Neither the initial nor the late hemodynamic results appeared affected by any definable procedural variable at the time of valvuloplasty, including the maximal diameter of balloons, number of balloons simultaneously used, mean inflation time or total number of inflations. Such technical concerns also did not seem to affect short- or long-term outcome. Similarly, no baseline hemodynamic variable clearly separated those who became increasingly symptomatic from those whose condition was improved at the 6 month interval. At recatheterization, a reduction in the aortic valve area toward baseline was observed in 24 (62%) of the 39 improved patients and in 45 (80%) of the 56 who were symptomatic.(ABSTRACT TRUNCATED AT 250 WORDS)

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Am Coll Cardiol

DOI

ISSN

0735-1097

Publication Date

April 1991

Volume

17

Issue

5

Start / End Page

1188 / 1195

Location

United States

Related Subject Headings

  • Recurrence
  • Male
  • Humans
  • Hemodynamics
  • Follow-Up Studies
  • Female
  • Catheterization
  • Cardiovascular System & Hematology
  • Aortic Valve Stenosis
  • Aortic Valve
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Bashore, T. M., & Davidson, C. J. (1991). Follow-up recatheterization after balloon aortic valvuloplasty. Mansfield Scientific Aortic Valvuloplasty Registry Investigators. J Am Coll Cardiol, 17(5), 1188–1195. https://doi.org/10.1016/0735-1097(91)90853-2
Bashore, T. M., and C. J. Davidson. “Follow-up recatheterization after balloon aortic valvuloplasty. Mansfield Scientific Aortic Valvuloplasty Registry Investigators.J Am Coll Cardiol 17, no. 5 (April 1991): 1188–95. https://doi.org/10.1016/0735-1097(91)90853-2.
Bashore, T. M., and C. J. Davidson. “Follow-up recatheterization after balloon aortic valvuloplasty. Mansfield Scientific Aortic Valvuloplasty Registry Investigators.J Am Coll Cardiol, vol. 17, no. 5, Apr. 1991, pp. 1188–95. Pubmed, doi:10.1016/0735-1097(91)90853-2.
Journal cover image

Published In

J Am Coll Cardiol

DOI

ISSN

0735-1097

Publication Date

April 1991

Volume

17

Issue

5

Start / End Page

1188 / 1195

Location

United States

Related Subject Headings

  • Recurrence
  • Male
  • Humans
  • Hemodynamics
  • Follow-Up Studies
  • Female
  • Catheterization
  • Cardiovascular System & Hematology
  • Aortic Valve Stenosis
  • Aortic Valve