Recovery of localized defects in PET attenuation-correction images

Publication ,  Journal Article
Laymon, CM; Bowsher, JE; Turkington, TG
Published in: IEEE Nuclear Science Symposium Conference Record
January 1, 2003

CT data from PET/CT can be used to produce a 511-keV attenuation map of high statistical quality for PET attenuation correction. However, CT contrast agents can result in regions of overestimated 511 keV attenuation-coefficient values. Resulting attenuation corrected emission images have been observed with focal artifacts resembling diseased tissue We investigate a method for recovering the appropriate values of artifactual attenuation by using the measured emission data. The recovery problem is simplified by the assumption of an otherwise perfect attenuation map containing only limited regions of incorrectly assigned attenuation. Additionally a "binary" constraint may be applicable to the recovery of contrast induced artifacts in which it is assumed that a suspect pixel with a high attenuation coefficient value is either (a) correct or (b) misidentified contrast that should have the value of water. A demonstration recovery algorithm is introduced. To start, suspected regions within the attenuation map are defined. Such a region could be, for example, all pixels with high attenuation values. An iterative procedure is described in which in which updates of the attenuation and emission images are interleaved. In the attenuation case only pixel values within the defined regions are changed. The binary constraint is incorporated into the procedure. Results with several classes of digital phantoms yield perfect recovery in the noise free case. Stochastic noise degrades algorithm performance.

Duke Scholars

Published In

IEEE Nuclear Science Symposium Conference Record

DOI

ISSN

1095-7863

Publication Date

January 1, 2003

Volume

3

Start / End Page

1949 / 1952
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Laymon, C. M., Bowsher, J. E., & Turkington, T. G. (2003). Recovery of localized defects in PET attenuation-correction images. IEEE Nuclear Science Symposium Conference Record, 3, 1949–1952. https://doi.org/10.1109/nssmic.2003.1352261
Laymon, C. M., J. E. Bowsher, and T. G. Turkington. “Recovery of localized defects in PET attenuation-correction images.” IEEE Nuclear Science Symposium Conference Record 3 (January 1, 2003): 1949–52. https://doi.org/10.1109/nssmic.2003.1352261.
Laymon CM, Bowsher JE, Turkington TG. Recovery of localized defects in PET attenuation-correction images. IEEE Nuclear Science Symposium Conference Record. 2003 Jan 1;3:1949–52.
Laymon, C. M., et al. “Recovery of localized defects in PET attenuation-correction images.” IEEE Nuclear Science Symposium Conference Record, vol. 3, Jan. 2003, pp. 1949–52. Scopus, doi:10.1109/nssmic.2003.1352261.
Laymon CM, Bowsher JE, Turkington TG. Recovery of localized defects in PET attenuation-correction images. IEEE Nuclear Science Symposium Conference Record. 2003 Jan 1;3:1949–1952.

Published In

IEEE Nuclear Science Symposium Conference Record

DOI

ISSN

1095-7863

Publication Date

January 1, 2003

Volume

3

Start / End Page

1949 / 1952