Skip to main content
Journal cover image

Radiographic correlation of hallux MP fusion position and plate angle.

Publication ,  Journal Article
Leaseburg, JT; DeOrio, JK; Shapiro, SA
Published in: Foot Ankle Int
September 2009

BACKGROUND: This study assessed the variability of plate bend in regard to final metatarsophalangeal (MP) fusion angles and toe-to-floor distance. We hypothesized that the final MP angle, the angle of the proximal phalanx to the floor, and the weightbearing toe-to-floor distance would be dictated solely by the magnitude of the bend in the plate. MATERIALS AND METHODS: This is a retrospective analysis of 35 sequential patients who underwent MP fusion with a low-contour titanium plate. Postoperative weightbearing radiographs were analyzed for plate angle, MP fusion angle, the angle of the proximal phalanx to the floor, and the weightbearing toe-to-floor distance. RESULTS: We found statistical correlation between plate angle and MP angle and between plate angle and the angle of the proximal phalanx to the floor. However, there was low correlation between plate angle and with toe-to-floor distance. In addition, we noted many outliers, which resulted in higher or lower correlation of the MP angle to the expected plate angle and, thus, a relationship between angles that was far from linear. CONCLUSION: Care needs to be taken when relying solely on the bend in the plate to determine the final position of the toe in MP fusions. Although the association between plate bend and MP angle and proximal phalanx to floor angle was strong, the association between the bend in the plate and weight bearing toe-to-floor distance was variable. This could result in the toe hitting the shoe or the need to vault over the toe. Therefore, the surgeon must match the plate to each patient's anatomy to ensure proper weight bearing toe-to-floor distance and not rely on plate angle exclusively.

Duke Scholars

Published In

Foot Ankle Int

DOI

ISSN

1071-1007

Publication Date

September 2009

Volume

30

Issue

9

Start / End Page

873 / 876

Location

United States

Related Subject Headings

  • Weight-Bearing
  • Treatment Outcome
  • Toe Phalanges
  • Retrospective Studies
  • Radiography
  • Orthopedics
  • Middle Aged
  • Metatarsophalangeal Joint
  • Male
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Leaseburg, J. T., DeOrio, J. K., & Shapiro, S. A. (2009). Radiographic correlation of hallux MP fusion position and plate angle. Foot Ankle Int, 30(9), 873–876. https://doi.org/10.3113/FAI.2009.0873
Leaseburg, J Thaddeus, James K. DeOrio, and Shane A. Shapiro. “Radiographic correlation of hallux MP fusion position and plate angle.Foot Ankle Int 30, no. 9 (September 2009): 873–76. https://doi.org/10.3113/FAI.2009.0873.
Leaseburg JT, DeOrio JK, Shapiro SA. Radiographic correlation of hallux MP fusion position and plate angle. Foot Ankle Int. 2009 Sep;30(9):873–6.
Leaseburg, J. Thaddeus, et al. “Radiographic correlation of hallux MP fusion position and plate angle.Foot Ankle Int, vol. 30, no. 9, Sept. 2009, pp. 873–76. Pubmed, doi:10.3113/FAI.2009.0873.
Leaseburg JT, DeOrio JK, Shapiro SA. Radiographic correlation of hallux MP fusion position and plate angle. Foot Ankle Int. 2009 Sep;30(9):873–876.
Journal cover image

Published In

Foot Ankle Int

DOI

ISSN

1071-1007

Publication Date

September 2009

Volume

30

Issue

9

Start / End Page

873 / 876

Location

United States

Related Subject Headings

  • Weight-Bearing
  • Treatment Outcome
  • Toe Phalanges
  • Retrospective Studies
  • Radiography
  • Orthopedics
  • Middle Aged
  • Metatarsophalangeal Joint
  • Male
  • Humans