The lead glass columns: A large shower detector at the SLAC hybrid facility

Published

Journal Article

A large lead glass shower detector containing 204 lead glass blocks and 250 finger hodoscope elements has been constructed and operated in a photoproduction experiment at the SLAC Hybrid facility. An energy resolution of σE/E = (0.84+4.8/E 1 2)% has been achieved for electron energies between 4 and 16 GeV. Details of the apparatus, its stability monitoring system, and its use in triggering the bubble chamber are presented. The performance of the detector in electron identification and π0 reconstruction is discussed. © 1982.

Full Text

Duke Authors

Cited Authors

  • Brau, JE; Butler, J; Bugg, WM; Carroll, JT; Cautis, CV; Cohn, HO; Condo, G; Dado, S; Davenport, F; Diamond, R; Erickson, R; Ferguson, M; Field, RC; Fortney, LR; Franek, B; Gearhart, R; Glanzman, T; Goldberg, J; Goshaw, AT; Hagopian, V; Handler, T; Hargis, HJ; Hart, E; Huang, DQ; Kelsey, DP; Lannutti, J; Lucas, PW; Moffeit, KC; Maruyama, T; Palounek, APT; Parker, DB; Rafatian, A; Robertson, WJ; Rogers, AH; Sugahara, R; Takahashi, K; Tether, S; Walker, WD; Yamaguchi, A; Yamamoto, RK

Published Date

  • May 15, 1982

Published In

Volume / Issue

  • 196 / 2-3

Start / End Page

  • 403 - 413

International Standard Serial Number (ISSN)

  • 0029-554X

Digital Object Identifier (DOI)

  • 10.1016/0029-554X(82)90105-7

Citation Source