We describe the characteristics of silicon microstrip sensors fabricated by Hamamatsu Photonics for the CDF Run 2b silicon detector. A total of 953 sensors, including 117 prototype sensors, have been produced and tested. Five sensors were irradiated with neutrons up to 1.4 × 1014 n/cm2 as a part of the sensor quality assurance program. The electrical and mechanical characteristics are found to be superior in all aspects and fulfill our specifications. We comment on charge-up susceptibility of the sensors that employ a (100) crystal structure.

Duke Scholars

Published In

IEEE Transactions on Nuclear Science

DOI

ISSN

0018-9499

Publication Date

August 1, 2004

Volume

51

Issue

4 I

Start / End Page

1546 / 1554

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Akimoto, T., Aoki, M., Hara, K., Kim, S., Nakamura, Y., Yoshitama, H., … Riipinen, P. (2004). Sensors for the CDF Run2b silicon detector. IEEE Transactions on Nuclear Science, 51(4 I), 1546–1554. https://doi.org/10.1109/TNS.2004.832586
Akimoto, T., M. Aoki, K. Hara, S. Kim, Y. Nakamura, H. Yoshitama, P. Azzi, et al. “Sensors for the CDF Run2b silicon detector.” IEEE Transactions on Nuclear Science 51, no. 4 I (August 1, 2004): 1546–54. https://doi.org/10.1109/TNS.2004.832586.
Akimoto T, Aoki M, Hara K, Kim S, Nakamura Y, Yoshitama H, et al. Sensors for the CDF Run2b silicon detector. IEEE Transactions on Nuclear Science. 2004 Aug 1;51(4 I):1546–54.
Akimoto, T., et al. “Sensors for the CDF Run2b silicon detector.” IEEE Transactions on Nuclear Science, vol. 51, no. 4 I, Aug. 2004, pp. 1546–54. Scopus, doi:10.1109/TNS.2004.832586.
Akimoto T, Aoki M, Hara K, Kim S, Nakamura Y, Yoshitama H, Azzi P, Bacchetta N, Bisello D, Busetto G, Manea C, Pantano D, Wang Z, Behari S, Maksimovic P, Nord B, Pursley J, Schuyler B, Benjamin D, Cabrera S, Kruse M, Bolla G, Bortoletto D, Canepa A, Fernandez JP, Novak J, Booth P, Cooke P, Burghard A, Gorelov I, Hoeferkamp M, Naoumov D, Seidel S, Watje P, Cardoso G, Derylo G, Fang I, Flaugher B, Hoff J, Hrycyk M, Lukens P, Merkel P, Moccia S, Nelson T, Orlov Y, Pavlicek V, Shenai A, Wester W, Yarema R, Yun JC, Zimmerman T, Chertok M, Holbrook B, Lander R, Landry T, Pellett D, Soha A, Yao W, Ciobanu CI, Hsiung TH, Junk T, Feng EJ, Freeman J, Galtieri L, Garcia-Sciveres M, Haber C, Krieger B, Lujan PJ, Mandelli E, von der Lippe H, Walder JP, Weber M, Zetti F, Zimmermann S, Galyardt J, Giurgiu G, Hale D, Hill C, Incandela J, Kyre S, Stuart D, Harr R, Hong SC, Jeon EJ, Joo KK, Kong DJ, Lee J, Min SN, Yang YC, Kahkola H, Karjalainen S, Tavi M, Kobayashi K, Nakano I, Tanaka R, Lauhakangas R, Orava R, Osterberg K, Riipinen P. Sensors for the CDF Run2b silicon detector. IEEE Transactions on Nuclear Science. 2004 Aug 1;51(4 I):1546–1554.

Published In

IEEE Transactions on Nuclear Science

DOI

ISSN

0018-9499

Publication Date

August 1, 2004

Volume

51

Issue

4 I

Start / End Page

1546 / 1554

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics