Skip to main content

RADAR reference adult, pediatric, and pregnant female phantom series for internal and external dosimetry.

Publication ,  Journal Article
Stabin, MG; Xu, XG; Emmons, MA; Segars, WP; Shi, C; Fernald, MJ
Published in: J Nucl Med
November 2012

UNLABELLED: A new generation of reference computational phantoms, based on image-based models tied to the reference masses defined by the International Commission on Radiological Protection (ICRP) for dose calculations, is presented. METHODS: Anatomic models based on nonuniform rational b-spline modeling techniques were used to define reference male and female adults, 15-y-olds, 10-y-olds, 5-y-olds, 1-y-olds, newborns, and pregnant women at 3 stages of gestation, using the defined reference organ masses in ICRP publication 89. Absorbed fractions and specific absorbed fractions for internal emitters were derived using standard Monte Carlo radiation transport simulation codes. RESULTS: Differences were notable between many pairs of organs in specific absorbed fractions because of the improved realism of the models, with adjacent organs usually closer and sometimes touching. Final estimates of absorbed dose for radiopharmaceuticals, for example, were only slightly different overall, as many of the differences were small and most pronounced at low radiation energies. Some new important organs were defined (salivary glands, prostate, eyes, and esophagus), and the identity of a few gastrointestinal tract organs changed. CONCLUSION: A new generation of reference models for standardized internal and external dose calculations has been defined. The models will be implemented in standardized software for internal dose calculations and be used to produce new standardized dose estimates for radiopharmaceuticals and other applications.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Nucl Med

DOI

EISSN

1535-5667

Publication Date

November 2012

Volume

53

Issue

11

Start / End Page

1807 / 1813

Location

United States

Related Subject Headings

  • Radiometry
  • Radiation Protection
  • Pregnancy
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Male
  • Infant, Newborn
  • Infant
  • Humans
  • Female
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Stabin, M. G., Xu, X. G., Emmons, M. A., Segars, W. P., Shi, C., & Fernald, M. J. (2012). RADAR reference adult, pediatric, and pregnant female phantom series for internal and external dosimetry. J Nucl Med, 53(11), 1807–1813. https://doi.org/10.2967/jnumed.112.106138
Stabin, Michael G., X George Xu, Mary A. Emmons, W Paul Segars, Chengyu Shi, and Michael J. Fernald. “RADAR reference adult, pediatric, and pregnant female phantom series for internal and external dosimetry.J Nucl Med 53, no. 11 (November 2012): 1807–13. https://doi.org/10.2967/jnumed.112.106138.
Stabin MG, Xu XG, Emmons MA, Segars WP, Shi C, Fernald MJ. RADAR reference adult, pediatric, and pregnant female phantom series for internal and external dosimetry. J Nucl Med. 2012 Nov;53(11):1807–13.
Stabin, Michael G., et al. “RADAR reference adult, pediatric, and pregnant female phantom series for internal and external dosimetry.J Nucl Med, vol. 53, no. 11, Nov. 2012, pp. 1807–13. Pubmed, doi:10.2967/jnumed.112.106138.
Stabin MG, Xu XG, Emmons MA, Segars WP, Shi C, Fernald MJ. RADAR reference adult, pediatric, and pregnant female phantom series for internal and external dosimetry. J Nucl Med. 2012 Nov;53(11):1807–1813.

Published In

J Nucl Med

DOI

EISSN

1535-5667

Publication Date

November 2012

Volume

53

Issue

11

Start / End Page

1807 / 1813

Location

United States

Related Subject Headings

  • Radiometry
  • Radiation Protection
  • Pregnancy
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Male
  • Infant, Newborn
  • Infant
  • Humans
  • Female