Skip to main content
Journal cover image

Evaluation of the Medtronic (Driver) cobalt-chromium alloy coronary stent system.

Publication ,  Journal Article
Sketch, MH; Ball, M; Rutherford, B; Popma, JJ; Russell, C; Kereiakes, DJ; Driver investigators,
Published in: Am J Cardiol
January 1, 2005

The Driver Registry was a prospective, multicenter, nonrandomized study to evaluate the clinical safety and efficacy of the Driver cobalt-chromium alloy stent. Use of the cobalt-chromium alloy in place of stainless steel offers enhanced visibility and radial strength with thinner structural elements. The registry enrolled 298 patients with symptomatic ischemic heart disease attributable to de novo or restenotic nonstented native lesions of a single vessel amenable to percutaneous stenting. The primary composite end point was the incidence of major adverse cardiac events (death, myocardial infarction, emergency bypass surgery, or target lesion revascularization) 180 days after enrollment. Quantitative coronary angiography was performed before and after the index stent deployment and repeated at 6 months in 83 patients. Mean patient age was 62.6 years, mean reference vessel diameter was 3.07 mm before the procedure, and mean lesion length was 11.04 mm. Fifty-one patients received multiple stents. Angiographic success rate was 100% and procedural success rate was 98.3%. Cumulative incidence of major adverse cardiac events was 5.7% and target lesion revascularization was 3.4% at 180 days. In-stent late loss was 0.94 mm at 180 days, and no subacute stent thromboses were observed. This registry demonstrated the safety and efficacy of this novel coronary stent platform.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Am J Cardiol

DOI

ISSN

0002-9149

Publication Date

January 1, 2005

Volume

95

Issue

1

Start / End Page

8 / 12

Location

United States

Related Subject Headings

  • Time Factors
  • Stents
  • Prosthesis Design
  • Prospective Studies
  • Middle Aged
  • Male
  • Humans
  • Follow-Up Studies
  • Female
  • Coronary Stenosis
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Sketch, M. H., Ball, M., Rutherford, B., Popma, J. J., Russell, C., Kereiakes, D. J., & Driver investigators, . (2005). Evaluation of the Medtronic (Driver) cobalt-chromium alloy coronary stent system. Am J Cardiol, 95(1), 8–12. https://doi.org/10.1016/j.amjcard.2004.08.055
Sketch, Michael H., Michael Ball, Barry Rutherford, Jeffrey J. Popma, Catherine Russell, Dean J. Kereiakes, and Dean J. Driver investigators. “Evaluation of the Medtronic (Driver) cobalt-chromium alloy coronary stent system.Am J Cardiol 95, no. 1 (January 1, 2005): 8–12. https://doi.org/10.1016/j.amjcard.2004.08.055.
Sketch MH, Ball M, Rutherford B, Popma JJ, Russell C, Kereiakes DJ, et al. Evaluation of the Medtronic (Driver) cobalt-chromium alloy coronary stent system. Am J Cardiol. 2005 Jan 1;95(1):8–12.
Sketch, Michael H., et al. “Evaluation of the Medtronic (Driver) cobalt-chromium alloy coronary stent system.Am J Cardiol, vol. 95, no. 1, Jan. 2005, pp. 8–12. Pubmed, doi:10.1016/j.amjcard.2004.08.055.
Sketch MH, Ball M, Rutherford B, Popma JJ, Russell C, Kereiakes DJ, Driver investigators. Evaluation of the Medtronic (Driver) cobalt-chromium alloy coronary stent system. Am J Cardiol. 2005 Jan 1;95(1):8–12.
Journal cover image

Published In

Am J Cardiol

DOI

ISSN

0002-9149

Publication Date

January 1, 2005

Volume

95

Issue

1

Start / End Page

8 / 12

Location

United States

Related Subject Headings

  • Time Factors
  • Stents
  • Prosthesis Design
  • Prospective Studies
  • Middle Aged
  • Male
  • Humans
  • Follow-Up Studies
  • Female
  • Coronary Stenosis