The Worthington "ultrafree" device evaluated for determination of ultrafiltrable calcium in serum.

Publication ,  Journal Article
Toffaletti, J; Tompkins, D; Hoff, G
Published in: Clin Chem
March 1981

We evaluated a commercially-available disposable device ("Ultrafree," Worthington Diagnostics) for the anaerobic preparation of protein-free ultrafiltrates from serum for measurement of ultrafiltrable calcium. Sufficient filtrate for the analysis is obtained with 10 min from 0.2 to 0.4 mL of serum at room temperature. We assessed these ultrafilters with regard to permeability of calcium citrate, exclusion of proteins, frequency of leakage, and effect of temperature on results. Within-run and day-to-day coefficients of variation for human serum pools were 1.2 and 1.5%, respectively. Reference intervals (in mmol/L) for total (2.16-2.58), ultrafiltrable (1.44-1.67), dialyzable (1.25-1.41), and ionized (1.04-1.25) calcium have been determined for a healthy population of 69 women and 81 men, ages to 18 to 65 years. The device appears to be the most practicable yet available for use in making this measurement.

Duke Scholars

Published In

Clin Chem

ISSN

0009-9147

Publication Date

March 1981

Volume

27

Issue

3

Start / End Page

466 / 468

Location

England

Related Subject Headings

  • Ultrafiltration
  • Temperature
  • Spectrophotometry, Atomic
  • Molecular Weight
  • Middle Aged
  • Male
  • Humans
  • General Clinical Medicine
  • Female
  • Calcium
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Toffaletti, J., Tompkins, D., & Hoff, G. (1981). The Worthington "ultrafree" device evaluated for determination of ultrafiltrable calcium in serum. Clin Chem, 27(3), 466–468.
Toffaletti, J., D. Tompkins, and G. Hoff. “The Worthington "ultrafree" device evaluated for determination of ultrafiltrable calcium in serum.Clin Chem 27, no. 3 (March 1981): 466–68.
Toffaletti J, Tompkins D, Hoff G. The Worthington "ultrafree" device evaluated for determination of ultrafiltrable calcium in serum. Clin Chem. 1981 Mar;27(3):466–8.
Toffaletti, J., et al. “The Worthington "ultrafree" device evaluated for determination of ultrafiltrable calcium in serum.Clin Chem, vol. 27, no. 3, Mar. 1981, pp. 466–68.
Toffaletti J, Tompkins D, Hoff G. The Worthington "ultrafree" device evaluated for determination of ultrafiltrable calcium in serum. Clin Chem. 1981 Mar;27(3):466–468.

Published In

Clin Chem

ISSN

0009-9147

Publication Date

March 1981

Volume

27

Issue

3

Start / End Page

466 / 468

Location

England

Related Subject Headings

  • Ultrafiltration
  • Temperature
  • Spectrophotometry, Atomic
  • Molecular Weight
  • Middle Aged
  • Male
  • Humans
  • General Clinical Medicine
  • Female
  • Calcium