Multileaf collimators were applied to intensity modulated lateral fields to achieve a relatively homogeneous dose distribution in the head and neck region without using any wedges. Then the isodose distribution was compared with one planned with wedges. As a result, the many advantages of intensity modulated planning were highlighted.

Duke Scholars

Published In

Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

DOI

ISSN

0589-1019

Publication Date

January 1, 2000

Volume

1

Start / End Page

232 / 234
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wang, Z., Sibata, C. H., Wu, Q. J., & Kinsella, T. J. (2000). A reliable intensity modulated radiation therapy approach with multiple opposed lateral fields for head and neck tumors. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings, 1, 232–234. https://doi.org/10.1109/IEMBS.2000.900713
Wang, Z., C. H. Sibata, Q. J. Wu, and T. J. Kinsella. “A reliable intensity modulated radiation therapy approach with multiple opposed lateral fields for head and neck tumors.” Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings 1 (January 1, 2000): 232–34. https://doi.org/10.1109/IEMBS.2000.900713.
Wang Z, Sibata CH, Wu QJ, Kinsella TJ. A reliable intensity modulated radiation therapy approach with multiple opposed lateral fields for head and neck tumors. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 2000 Jan 1;1:232–4.
Wang, Z., et al. “A reliable intensity modulated radiation therapy approach with multiple opposed lateral fields for head and neck tumors.” Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings, vol. 1, Jan. 2000, pp. 232–34. Scopus, doi:10.1109/IEMBS.2000.900713.
Wang Z, Sibata CH, Wu QJ, Kinsella TJ. A reliable intensity modulated radiation therapy approach with multiple opposed lateral fields for head and neck tumors. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 2000 Jan 1;1:232–234.

Published In

Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

DOI

ISSN

0589-1019

Publication Date

January 1, 2000

Volume

1

Start / End Page

232 / 234