Skip to main content
Journal cover image

An equivalent length model of microdialysis sampling.

Publication ,  Journal Article
Tong, S; Yuan, F
Published in: Journal of pharmaceutical and biomedical analysis
April 2002

One of the critical issues in microdialysis sampling is how to predict the extraction fraction (E(d)), based on transport properties of analytes in both tissues and probes. A one-dimensional (1-D) model has been used widely in previous studies to predict E(d) at the steady state. However, this model is valid only for long probes. To this end, an equivalent length (EL) model was developed for probes with any length used in experiments. The key idea in the model was to replace the probe length (L) in the 1-D model with an equivalent length (L(E)) when calculating transport resistance in surrounding tissues. The length difference, (L(E)-L), was assumed to be proportional to the penetration depth of analytes (Gamma). The proportionality constant (lambda) was determined through minimizing the errors in predicted E(d). We found that, the EL model could accurately predict E(d) when lambda=0.369. The maximum error in EL model predictions was <6%, for model constants varying in the same ranges as those in microdialysis experiments. This error was one order of magnitude smaller than that in 1-D model predictions.

Duke Scholars

Published In

Journal of pharmaceutical and biomedical analysis

DOI

EISSN

1873-264X

ISSN

0731-7085

Publication Date

April 2002

Volume

28

Issue

2

Start / End Page

269 / 278

Related Subject Headings

  • Models, Theoretical
  • Microdialysis
  • Membranes, Artificial
  • Diffusion
  • Analytical Chemistry
  • Algorithms
  • 3401 Analytical chemistry
  • 3214 Pharmacology and pharmaceutical sciences
  • 1115 Pharmacology and Pharmaceutical Sciences
  • 0301 Analytical Chemistry
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tong, S., & Yuan, F. (2002). An equivalent length model of microdialysis sampling. Journal of Pharmaceutical and Biomedical Analysis, 28(2), 269–278. https://doi.org/10.1016/s0731-7085(01)00565-9
Tong, Sheng, and Fan Yuan. “An equivalent length model of microdialysis sampling.Journal of Pharmaceutical and Biomedical Analysis 28, no. 2 (April 2002): 269–78. https://doi.org/10.1016/s0731-7085(01)00565-9.
Tong S, Yuan F. An equivalent length model of microdialysis sampling. Journal of pharmaceutical and biomedical analysis. 2002 Apr;28(2):269–78.
Tong, Sheng, and Fan Yuan. “An equivalent length model of microdialysis sampling.Journal of Pharmaceutical and Biomedical Analysis, vol. 28, no. 2, Apr. 2002, pp. 269–78. Epmc, doi:10.1016/s0731-7085(01)00565-9.
Tong S, Yuan F. An equivalent length model of microdialysis sampling. Journal of pharmaceutical and biomedical analysis. 2002 Apr;28(2):269–278.
Journal cover image

Published In

Journal of pharmaceutical and biomedical analysis

DOI

EISSN

1873-264X

ISSN

0731-7085

Publication Date

April 2002

Volume

28

Issue

2

Start / End Page

269 / 278

Related Subject Headings

  • Models, Theoretical
  • Microdialysis
  • Membranes, Artificial
  • Diffusion
  • Analytical Chemistry
  • Algorithms
  • 3401 Analytical chemistry
  • 3214 Pharmacology and pharmaceutical sciences
  • 1115 Pharmacology and Pharmaceutical Sciences
  • 0301 Analytical Chemistry