Closed reduction of a dislocation of a constrained acetabular component.

Published

Journal Article

A constrained acetabular liner occasionally is used in management of chronic instability after total hip arthroplasty. If dislocation occurs out of a constrained liner, open reduction is indicated. A case is presented of closed reduction of a femoral component into a constrained liner.