Skip to main content

Detection of E. coli using a microfluidics-based antibody biochip detection system.

Publication ,  Journal Article
Stokes, DL; Griffin, GD; Vo-Dinh, T
Published in: Fresenius' journal of analytical chemistry
February 2001

This work demonstrates the detection of E. coli using a 2-dimensional photosensor array biochip which is efficiently equipped with a microfluidics sample/reagent delivery system for on-chip monitoring of bioassays. The biochip features a 4 x 4 array of independently operating photodiodes that are integrated along with amplifiers, discriminators and logic circuitry on a single platform. The microfluidics system includes a single 0.4 mL reaction chamber which houses a sampling platform that selectively captures detection probes from a sample through the use of immobilized bioreceptors. The independently operating photodiodes allow simultaneous monitoring of multiple samples. In this study the sampling platform is a cellulosic membrane that is exposed to E. coli organisms and subsequently analyzed using a sandwich immunoassay involving a Cy5-labeled antibody probe. The combined effectiveness of the integrated circuit (IC) biochip and the immunoassay is evaluated for assays performed both by conventional laboratory means followed by detection with the IC biochip, and through the use of the microfluidics system for on-chip detection. Highlights of the studies show that the biochip has a linear dynamic range of three orders of magnitude observed for conventional assays, and can detect 20 E. coli organisms. Selective detection of E. coli in a complex medium, milk diluent, is also reported for both off-chip and on-chip assays.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Fresenius' journal of analytical chemistry

DOI

EISSN

1432-1130

ISSN

0937-0633

Publication Date

February 2001

Volume

369

Issue

3-4

Start / End Page

295 / 301

Related Subject Headings

  • Sensitivity and Specificity
  • Reproducibility of Results
  • Milk
  • Immunoassay
  • Escherichia coli
  • Equipment Design
  • Biosensing Techniques
  • Antibodies
  • Animals
  • Analytical Chemistry
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Stokes, D. L., Griffin, G. D., & Vo-Dinh, T. (2001). Detection of E. coli using a microfluidics-based antibody biochip detection system. Fresenius’ Journal of Analytical Chemistry, 369(3–4), 295–301. https://doi.org/10.1007/s002160000660
Stokes, D. L., G. D. Griffin, and T. Vo-Dinh. “Detection of E. coli using a microfluidics-based antibody biochip detection system.Fresenius’ Journal of Analytical Chemistry 369, no. 3–4 (February 2001): 295–301. https://doi.org/10.1007/s002160000660.
Stokes DL, Griffin GD, Vo-Dinh T. Detection of E. coli using a microfluidics-based antibody biochip detection system. Fresenius’ journal of analytical chemistry. 2001 Feb;369(3–4):295–301.
Stokes, D. L., et al. “Detection of E. coli using a microfluidics-based antibody biochip detection system.Fresenius’ Journal of Analytical Chemistry, vol. 369, no. 3–4, Feb. 2001, pp. 295–301. Epmc, doi:10.1007/s002160000660.
Stokes DL, Griffin GD, Vo-Dinh T. Detection of E. coli using a microfluidics-based antibody biochip detection system. Fresenius’ journal of analytical chemistry. 2001 Feb;369(3–4):295–301.

Published In

Fresenius' journal of analytical chemistry

DOI

EISSN

1432-1130

ISSN

0937-0633

Publication Date

February 2001

Volume

369

Issue

3-4

Start / End Page

295 / 301

Related Subject Headings

  • Sensitivity and Specificity
  • Reproducibility of Results
  • Milk
  • Immunoassay
  • Escherichia coli
  • Equipment Design
  • Biosensing Techniques
  • Antibodies
  • Animals
  • Analytical Chemistry