Generation of a suite of 3D computer-generated breast phantoms from a limited set of human subject data.

Publication ,  Journal Article
Hsu, CML; Palmeri, ML; Segars, WP; Veress, AI; Dobbins, JT
Published in: Med Phys
April 2013

PURPOSE: The authors previously reported on a three-dimensional computer-generated breast phantom, based on empirical human image data, including a realistic finite-element based compression model that was capable of simulating multimodality imaging data. The computerized breast phantoms are a hybrid of two phantom generation techniques, combining empirical breast CT (bCT) data with flexible computer graphics techniques. However, to date, these phantoms have been based on single human subjects. In this paper, the authors report on a new method to generate multiple phantoms, simulating additional subjects from the limited set of original dedicated breast CT data. The authors developed an image morphing technique to construct new phantoms by gradually transitioning between two human subject datasets, with the potential to generate hundreds of additional pseudoindependent phantoms from the limited bCT cases. The authors conducted a preliminary subjective assessment with a limited number of observers (n = 4) to illustrate how realistic the simulated images generated with the pseudoindependent phantoms appeared. METHODS: Several mesh-based geometric transformations were developed to generate distorted breast datasets from the original human subject data. Segmented bCT data from two different human subjects were used as the "base" and "target" for morphing. Several combinations of transformations were applied to morph between the "base' and "target" datasets such as changing the breast shape, rotating the glandular data, and changing the distribution of the glandular tissue. Following the morphing, regions of skin and fat were assigned to the morphed dataset in order to appropriately assign mechanical properties during the compression simulation. The resulting morphed breast was compressed using a finite element algorithm and simulated mammograms were generated using techniques described previously. Sixty-two simulated mammograms, generated from morphing three human subject datasets, were used in a preliminary observer evaluation where four board certified breast radiologists with varying amounts of experience ranked the level of realism (from 1 = "fake" to 10 = "real") of the simulated images. RESULTS: The morphing technique was able to successfully generate new and unique morphed datasets from the original human subject data. The radiologists evaluated the realism of simulated mammograms generated from the morphed and unmorphed human subject datasets and scored the realism with an average ranking of 5.87 ± 1.99, confirming that overall the phantom image datasets appeared more "real" than "fake." Moreover, there was not a significant difference (p > 0.1) between the realism of the unmorphed datasets (6.0 ± 1.95) compared to the morphed datasets (5.86 ± 1.99). Three of the four observers had overall average rankings of 6.89 ± 0.89, 6.9 ± 1.24, 6.76 ± 1.22, whereas the fourth observer ranked them noticeably lower at 2.94 ± 0.7. CONCLUSIONS: This work presents a technique that can be used to generate a suite of realistic computerized breast phantoms from a limited number of human subjects. This suite of flexible breast phantoms can be used for multimodality imaging research to provide a known truth while concurrently producing realistic simulated imaging data.

Duke Scholars

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

April 2013

Volume

40

Issue

4

Start / End Page

043703

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Models, Anatomic
  • Mammography
  • Imaging, Three-Dimensional
  • Humans
  • Female
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Hsu, C. M. L., Palmeri, M. L., Segars, W. P., Veress, A. I., & Dobbins, J. T. (2013). Generation of a suite of 3D computer-generated breast phantoms from a limited set of human subject data. Med Phys, 40(4), 043703. https://doi.org/10.1118/1.4794924
Hsu, Christina M. L., Mark L. Palmeri, W Paul Segars, Alexander I. Veress, and James T. Dobbins. “Generation of a suite of 3D computer-generated breast phantoms from a limited set of human subject data.Med Phys 40, no. 4 (April 2013): 043703. https://doi.org/10.1118/1.4794924.
Hsu CML, Palmeri ML, Segars WP, Veress AI, Dobbins JT. Generation of a suite of 3D computer-generated breast phantoms from a limited set of human subject data. Med Phys. 2013 Apr;40(4):043703.
Hsu, Christina M. L., et al. “Generation of a suite of 3D computer-generated breast phantoms from a limited set of human subject data.Med Phys, vol. 40, no. 4, Apr. 2013, p. 043703. Pubmed, doi:10.1118/1.4794924.
Hsu CML, Palmeri ML, Segars WP, Veress AI, Dobbins JT. Generation of a suite of 3D computer-generated breast phantoms from a limited set of human subject data. Med Phys. 2013 Apr;40(4):043703.

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

April 2013

Volume

40

Issue

4

Start / End Page

043703

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Models, Anatomic
  • Mammography
  • Imaging, Three-Dimensional
  • Humans
  • Female