Effect of defibrillation threshold testing on heart failure hospitalization or death in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT).

Publication ,  Journal Article
Aktas, MK; Huang, DT; Daubert, JP; Schuger, CD; McNitt, S; Goldenberg, I; Moss, AJ; Zareba, W
Published in: Heart Rhythm
February 2013

BACKGROUND: Defibrillation threshold (DFT) testing is commonly practiced at the time of implantable cardioverter-defibrillator (ICD) implant. The clinical consequence of ICD shocks delivered during DFT testing is unknown. OBJECTIVE: The purpose of this study was to determine the impact of ICD shocks and ICD shock energy level delivered during DFT testing in patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (MADIT-CRT) on clinical outcomes. METHODS: Patients who underwent DFT testing within 1 month of device implant were categorized by the number of ICD shocks delivered during DFT testing (0, 1, 2, ≥3 shocks) and according to high vs low (>20 J vs ≤20 J) energy ICD shocks. Clinical outcomes consisting of heart failure (HF) or death, death alone, HF alone, and ventricular tachycardia or ventricular fibrillation were analyzed in each group. RESULTS: DFT testing was performed in 1,659 patients within 1 month of device implant (1 shock in 365 patients, 2 shocks in 896 patients, 3+ shocks in 398 patients). High-energy ICD shocks were delivered in 609 patients. Increasing number of ICD shocks during DFT testing was not associated with an increase risk for the primary end-point of HF or death or for any of the secondary end-points of HF alone, VT/VF alone, or death. Delivery of high vs low-energy ICD shocks was not associated with adverse clinical outcomes. CONCLUSIONS: In patients with mild symptoms of HF, increasing number of ICD shocks and delivery of high energy ICD shocks during DFT testing was not associated with increased risk for HF or death or future VT/VF episodes.

Duke Scholars

Published In

Heart Rhythm

DOI

EISSN

1556-3871

Publication Date

February 2013

Volume

10

Issue

2

Start / End Page

193 / 199

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Time Factors
  • Tachycardia, Ventricular
  • Survival Rate
  • Statistics, Nonparametric
  • Severity of Illness Index
  • Risk Assessment
  • Proportional Hazards Models
  • Monitoring, Physiologic
  • Middle Aged
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Aktas, M. K., Huang, D. T., Daubert, J. P., Schuger, C. D., McNitt, S., Goldenberg, I., … Zareba, W. (2013). Effect of defibrillation threshold testing on heart failure hospitalization or death in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT). Heart Rhythm, 10(2), 193–199. https://doi.org/10.1016/j.hrthm.2012.10.024
Aktas, Mehmet K., David T. Huang, James P. Daubert, Claudio D. Schuger, Scott McNitt, Ilan Goldenberg, Arthur J. Moss, and Wojciech Zareba. “Effect of defibrillation threshold testing on heart failure hospitalization or death in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT).Heart Rhythm 10, no. 2 (February 2013): 193–99. https://doi.org/10.1016/j.hrthm.2012.10.024.
Journal cover image

Published In

Heart Rhythm

DOI

EISSN

1556-3871

Publication Date

February 2013

Volume

10

Issue

2

Start / End Page

193 / 199

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Time Factors
  • Tachycardia, Ventricular
  • Survival Rate
  • Statistics, Nonparametric
  • Severity of Illness Index
  • Risk Assessment
  • Proportional Hazards Models
  • Monitoring, Physiologic
  • Middle Aged