Correlation of cine MR imaging with two-dimensional pulsed Doppler echocardiography in valvular insufficiency.

Publication ,  Journal Article
Schiebler, M; Axel, L; Reichek, N; Aurigemma, G; Yeager, B; Douglas, P; Bogin, K; Kressel, H
Published in: J Comput Assist Tomogr
1987

Eight adults with known valvular insufficiency were studied with cine magnetic resonance (MR) imaging. Our cine MR uses cardiac synchronization of a rapid small flip angle pulse sequence on a 1.5 T MR system. Eleven regurgitant lesions (including aortic, mitral, and tricuspid valves) were imaged with both cine MR and two-dimensional pulsed Doppler echocardiography (2-DPDE). In each case of significant regurgitation the jet of valvular insufficiency was easily seen as a discrete area of low signal with cine MR. Not only was the regurgitant jet identified but also its relative severity agreed well with the 2-DPDE results. In two patients the regurgitant lesions were identified on cine MR prior to 2-DPDE. In addition to the regurgitant jet, chamber enlargement and wall thickening were also well demonstrated. Cine MR is a promising modality for both the detection and semiquantification of valvular insufficiency.

Duke Scholars

Published In

J Comput Assist Tomogr

DOI

ISSN

0363-8715

Publication Date

1987

Volume

11

Issue

4

Start / End Page

627 / 632

Location

United States

Related Subject Headings

  • Tricuspid Valve Insufficiency
  • Nuclear Medicine & Medical Imaging
  • Motion Pictures
  • Mitral Valve Insufficiency
  • Magnetic Resonance Spectroscopy
  • Humans
  • Heart Valve Diseases
  • Echocardiography
  • Aortic Valve Insufficiency
  • 4603 Computer vision and multimedia computation
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Schiebler, M., Axel, L., Reichek, N., Aurigemma, G., Yeager, B., Douglas, P., … Kressel, H. (1987). Correlation of cine MR imaging with two-dimensional pulsed Doppler echocardiography in valvular insufficiency. J Comput Assist Tomogr, 11(4), 627–632. https://doi.org/10.1097/00004728-198707000-00015
Schiebler, M., L. Axel, N. Reichek, G. Aurigemma, B. Yeager, P. Douglas, K. Bogin, and H. Kressel. “Correlation of cine MR imaging with two-dimensional pulsed Doppler echocardiography in valvular insufficiency.J Comput Assist Tomogr 11, no. 4 (1987): 627–32. https://doi.org/10.1097/00004728-198707000-00015.
Schiebler M, Axel L, Reichek N, Aurigemma G, Yeager B, Douglas P, et al. Correlation of cine MR imaging with two-dimensional pulsed Doppler echocardiography in valvular insufficiency. J Comput Assist Tomogr. 1987;11(4):627–32.
Schiebler, M., et al. “Correlation of cine MR imaging with two-dimensional pulsed Doppler echocardiography in valvular insufficiency.J Comput Assist Tomogr, vol. 11, no. 4, 1987, pp. 627–32. Pubmed, doi:10.1097/00004728-198707000-00015.
Schiebler M, Axel L, Reichek N, Aurigemma G, Yeager B, Douglas P, Bogin K, Kressel H. Correlation of cine MR imaging with two-dimensional pulsed Doppler echocardiography in valvular insufficiency. J Comput Assist Tomogr. 1987;11(4):627–632.

Published In

J Comput Assist Tomogr

DOI

ISSN

0363-8715

Publication Date

1987

Volume

11

Issue

4

Start / End Page

627 / 632

Location

United States

Related Subject Headings

  • Tricuspid Valve Insufficiency
  • Nuclear Medicine & Medical Imaging
  • Motion Pictures
  • Mitral Valve Insufficiency
  • Magnetic Resonance Spectroscopy
  • Humans
  • Heart Valve Diseases
  • Echocardiography
  • Aortic Valve Insufficiency
  • 4603 Computer vision and multimedia computation