Biomechanical comparison of stability of tibiotalocalcaneal arthrodesis with two different intramedullary retrograde nails.

Publication ,  Journal Article
Richter, M; Evers, J; Waehnert, D; Deorio, JK; Pinzur, M; Schulze, M; Zech, S; Ochman, S
Published in: Foot Ankle Surg
March 2014

BACKGROUND: The aim of the study was to compare the initial construct stability of two retrograde intramedullary nail systems for tibiotalocalcaneal arthrodesis (TTCF) (A3, Small Bone Innovations; HAN, Synthes) in a biomechanical cadaver study. METHODS: Nine pairs of human cadaver bones were instrumented with two different retrograde nail systems. One tibia from each pair was randomized to either rod. The bone mineral density was determined via tomography to ensure the characteristics in each pair of tibiae were similar. All tests were performed in load-control. Displacements and forces were acquired by the sensors of the machine at a rate of 64Hz. Specimens were tested in a stepwise progression starting with six times ±125N with a frequency of 1Hz for 250cycles each step was performed (1500cycles). The maximum load was then increased to ±250N for another 14 steps or until specimen failure occurred (up to 3500cycles). RESULTS: Average bone mineral density was 67.4mgHA/ccm and did not differ significantly between groups (t-test, p=.28). Under cyclic loading, the range of motion (dorsiflexion/plantarflexion) at 250N was significantly lower for the HAN-group with 7.2±2.3mm compared to the A3-group with 11.8±2.9mm (t-test, p<0.01). Failure was registered for the HAN after 4571±1134cycles and after 2344±1195cycles for the A3 (t-test, p=.031). Bone mineral density significantly correlated with the number of cycles to failure in both groups (Spearman-Rho, r>.69, p<0.01). CONCLUSIONS: The high specimen age and low bone density simulates an osteoporotic bone situation. The HAN with only lateral distal bend but two calcaneal locking screws showed higher stability (higher number of cycles to failure and lower motion such as dorsiflexion/plantarflexion during cyclic loading) than the A3 with additional distal dorsal bend but only one calcaneal locking screw. Both constructs showed sufficient stability compared with earlier data from a similar test model. CLINICAL RELEVANCE: The data suggest that both implants allow for sufficient primary stability for TTCF in osteoporotic and consequently also in non-osteoporotic bone. LEVEL OF EVIDENCE: Not applicable, experimental basic science study.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Foot Ankle Surg

DOI

EISSN

1460-9584

Publication Date

March 2014

Volume

20

Issue

1

Start / End Page

14 / 19

Location

France

Related Subject Headings

  • Tibia
  • Talus
  • Orthopedics
  • Male
  • Joint Instability
  • Humans
  • Female
  • Calcaneus
  • Cadaver
  • Bone Nails
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Richter, M., Evers, J., Waehnert, D., Deorio, J. K., Pinzur, M., Schulze, M., … Ochman, S. (2014). Biomechanical comparison of stability of tibiotalocalcaneal arthrodesis with two different intramedullary retrograde nails. Foot Ankle Surg, 20(1), 14–19. https://doi.org/10.1016/j.fas.2013.08.003
Richter, Martinus, Julia Evers, Dirk Waehnert, Jim K. Deorio, Michael Pinzur, Martin Schulze, Stefan Zech, and Sabine Ochman. “Biomechanical comparison of stability of tibiotalocalcaneal arthrodesis with two different intramedullary retrograde nails.Foot Ankle Surg 20, no. 1 (March 2014): 14–19. https://doi.org/10.1016/j.fas.2013.08.003.
Richter M, Evers J, Waehnert D, Deorio JK, Pinzur M, Schulze M, et al. Biomechanical comparison of stability of tibiotalocalcaneal arthrodesis with two different intramedullary retrograde nails. Foot Ankle Surg. 2014 Mar;20(1):14–9.
Richter, Martinus, et al. “Biomechanical comparison of stability of tibiotalocalcaneal arthrodesis with two different intramedullary retrograde nails.Foot Ankle Surg, vol. 20, no. 1, Mar. 2014, pp. 14–19. Pubmed, doi:10.1016/j.fas.2013.08.003.
Richter M, Evers J, Waehnert D, Deorio JK, Pinzur M, Schulze M, Zech S, Ochman S. Biomechanical comparison of stability of tibiotalocalcaneal arthrodesis with two different intramedullary retrograde nails. Foot Ankle Surg. 2014 Mar;20(1):14–19.
Journal cover image

Published In

Foot Ankle Surg

DOI

EISSN

1460-9584

Publication Date

March 2014

Volume

20

Issue

1

Start / End Page

14 / 19

Location

France

Related Subject Headings

  • Tibia
  • Talus
  • Orthopedics
  • Male
  • Joint Instability
  • Humans
  • Female
  • Calcaneus
  • Cadaver
  • Bone Nails