Skip to main content
Journal cover image

Assessment of vascular contrast and wall motion of the aortic root and ascending aorta on MDCT angiography: dual-source high-pitch vs non-gated single-source acquisition schemes.

Publication ,  Journal Article
Christensen, JD; Seaman, DM; Lungren, MP; Hurwitz, LM; Boll, DT
Published in: Eur Radiol
May 2014

OBJECTIVES: This retrospective study assessed whether dual-source high-pitch computed tomographic angiography (CTA) offered advantages over single-source standard-pitch techniques in the evaluation of the ascending aorta. METHODS: Twenty patients who received both thoracic dual-source high-pitch and single-source standard-pitch CTAs within 1 year were assessed. Dual-source CTAs were performed; standard-pitch imaging used dose-modulated 120 kVp/150 mAs and 0.8 pitch compared with high-pitch protocols employing dose-modulated 120 kVp/250 mAs and 2.4 target pitch. Radiation dose was documented. Contrast-to-noise ratios (CNRs) at sinuses of the Valsalva (CNRValsalva) and ascending aorta (CNRAorta) were calculated. Dose/CNR for each technique was compared with paired t-tests. Motion at aortic valve, aortic root and ascending aorta were assessed with four-point scales and Mann-Whitney U tests; longitudinal extension of motion was compared with paired t-tests. RESULTS: Significantly lower motion scores for high-pitch, compared with standard-pitch acquisitions for aortic annulus, 0 vs. 2, aortic root, 0 vs. 3, and ascending aorta, 0 vs. 2, were achieved. Significantly reduced longitudinal extension of motion at aortic root, 4.9 mm vs 15.7 mm, and ascending aorta, 4.9 mm vs 21.6 mm, was observed. Contrast was not impacted: CNRValsalva, 45.6 vs 46.3, and CNRAorta, 45.3 vs 47.1. CTDIvol was significantly decreased for high-pitch acquisitions, 13.9 mGy vs 15.8 mGy. CONCLUSIONS: Dual-source high-pitch CTAs significantly decreased motion artefact without negatively impacting vascular contrast and radiation dose. KEY POINTS: • Dual-source high-pitch CTA significantly decreased motion artefact of the ascending aorta. • Dual-source high-pitch CTA did not negatively impact on vascular contrast. • Dual-source high-pitch CTA significantly decreased radiation dose compared with single-source standard-pitch acquisitions.

Duke Scholars

Published In

Eur Radiol

DOI

EISSN

1432-1084

Publication Date

May 2014

Volume

24

Issue

5

Start / End Page

990 / 997

Location

Germany

Related Subject Headings

  • Young Adult
  • Tomography, X-Ray Computed
  • Retrospective Studies
  • Radiation Dosage
  • Nuclear Medicine & Medical Imaging
  • Movement
  • Middle Aged
  • Male
  • Humans
  • Female
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Christensen, J. D., Seaman, D. M., Lungren, M. P., Hurwitz, L. M., & Boll, D. T. (2014). Assessment of vascular contrast and wall motion of the aortic root and ascending aorta on MDCT angiography: dual-source high-pitch vs non-gated single-source acquisition schemes. Eur Radiol, 24(5), 990–997. https://doi.org/10.1007/s00330-014-3120-2
Christensen, Jared D., Danielle M. Seaman, Matthew P. Lungren, Lynne M. Hurwitz, and Daniel T. Boll. “Assessment of vascular contrast and wall motion of the aortic root and ascending aorta on MDCT angiography: dual-source high-pitch vs non-gated single-source acquisition schemes.Eur Radiol 24, no. 5 (May 2014): 990–97. https://doi.org/10.1007/s00330-014-3120-2.
Christensen, Jared D., et al. “Assessment of vascular contrast and wall motion of the aortic root and ascending aorta on MDCT angiography: dual-source high-pitch vs non-gated single-source acquisition schemes.Eur Radiol, vol. 24, no. 5, May 2014, pp. 990–97. Pubmed, doi:10.1007/s00330-014-3120-2.
Journal cover image

Published In

Eur Radiol

DOI

EISSN

1432-1084

Publication Date

May 2014

Volume

24

Issue

5

Start / End Page

990 / 997

Location

Germany

Related Subject Headings

  • Young Adult
  • Tomography, X-Ray Computed
  • Retrospective Studies
  • Radiation Dosage
  • Nuclear Medicine & Medical Imaging
  • Movement
  • Middle Aged
  • Male
  • Humans
  • Female