RTOG 0631 Phase II/III Study of Image-Guided Stereotactic Radiosurgery for Localized (1-3) Spine Metastases: Phase II Results.
PURPOSE: The phase II component of RTOG 0631 assessed the feasibility and safety of spine radiosurgery (SRS) for localized spine metastases in a cooperative group setting. MATERIALS AND METHODS: Patients with 1-3 spine metastasis with a Numerical Rating Pain Scale (NRPS) score ≥ 5 received 16 Gy single fraction SRS. The primary endpoint was SRS feasibility: image-guidance RT (IGRT) targeting accuracy ≤ 2mm, target volume coverage > 90% of prescription dose, maintaining spinal cord dose constraints (10 Gy to ≤ 10% of the cord volume from 5-6mm above to 5-6mm below the target or absolute spinal cord volume < 0.35cc) and other normal tissue dose constraints. A feasibility success rate < 70% was considered unacceptable for continuation of the phase III component. Based on the one-sample exact binomial test with α=0.10 (1-sided), 41 patients were required. Acute toxicity was assessed using the National Cancer Institute Common Toxicity Criteria for Adverse Events, version 3.0. RESULTS: Sixty-five institutions were credentialed with spine phantom dosimetry and IGRT compliance. Forty-six patients were accrued, and 44 were eligible. There were 4 cervical, 21 thoracic and 19 lumbar sites. Median NRPS was 7 at presentation. Final pre-treatment rapid review was approved in 100%. Accuracy of image-guided SRS targeting was in compliance with the protocol in 95%. The target coverage and spinal cord dose constraint were in accordance with the protocol requirements in 100% and 97%. Overall compliance for other normal tissue constraints was per protocol in 74%. There were no cases of grade 4-5 acute treatment-related toxicity. CONCLUSION: The phase II results demonstrate the feasibility and accurate use of SRS to treat spinal metastases, with rigorous quality control, in a cooperative group setting. The planned RTOG 0631 phase III component will proceed to compare pain relief and quality of life between SRS and external beam radiotherapy.
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
DOI
EISSN
Publication Date
Volume
Issue
Start / End Page
Location
Related Subject Headings
- Oncology & Carcinogenesis
- 5105 Medical and biological physics
- 3407 Theoretical and computational chemistry
- 3211 Oncology and carcinogenesis
- 1112 Oncology and Carcinogenesis
- 1103 Clinical Sciences
- 0299 Other Physical Sciences
Citation
Published In
DOI
EISSN
Publication Date
Volume
Issue
Start / End Page
Location
Related Subject Headings
- Oncology & Carcinogenesis
- 5105 Medical and biological physics
- 3407 Theoretical and computational chemistry
- 3211 Oncology and carcinogenesis
- 1112 Oncology and Carcinogenesis
- 1103 Clinical Sciences
- 0299 Other Physical Sciences