Skip to main content
Journal cover image

Determining the physical limits on semi-active control performance: A tutorial

Publication ,  Journal Article
Harvey, PS; Gavin, HP; Scruggs, JT; Rinker, JM
Published in: Structural Control and Health Monitoring
January 1, 2014

Control forces in semi-active control systems are constrained by the dynamics of actuators that regulate energy transmission through variable damping and/or stiffness mechanisms. The potential benefit of the development and implementation of new semi-active control devices and applications can be determined by optimizing the controlled performance subject to the constraints of the dynamics of the system being controlled (given by the state equations), the constraints associated with the dynamics of the semi-active device, and the expected external forcing. Performance optimization of semi-active control systems is a constrained two-point boundary value problem. This paper shows how this constrained problem can be transformed into an unconstrained problem, and how to easily solve the related unconstrained problem with Matlab. The method is illustrated on the performance optimization of a simple semi-active tuned-mass-damper for a structure subjected to ground accelerations. Several possible extensions of this method and application are offered. Copyright © 2013 John Wiley & Sons, Ltd.

Duke Scholars

Published In

Structural Control and Health Monitoring

DOI

EISSN

1545-2263

ISSN

1545-2255

Publication Date

January 1, 2014

Volume

21

Issue

5

Start / End Page

803 / 816

Related Subject Headings

  • Civil Engineering
  • 4005 Civil engineering
  • 0905 Civil Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Harvey, P. S., Gavin, H. P., Scruggs, J. T., & Rinker, J. M. (2014). Determining the physical limits on semi-active control performance: A tutorial. Structural Control and Health Monitoring, 21(5), 803–816. https://doi.org/10.1002/stc.1602
Harvey, P. S., H. P. Gavin, J. T. Scruggs, and J. M. Rinker. “Determining the physical limits on semi-active control performance: A tutorial.” Structural Control and Health Monitoring 21, no. 5 (January 1, 2014): 803–16. https://doi.org/10.1002/stc.1602.
Harvey PS, Gavin HP, Scruggs JT, Rinker JM. Determining the physical limits on semi-active control performance: A tutorial. Structural Control and Health Monitoring. 2014 Jan 1;21(5):803–16.
Harvey, P. S., et al. “Determining the physical limits on semi-active control performance: A tutorial.” Structural Control and Health Monitoring, vol. 21, no. 5, Jan. 2014, pp. 803–16. Scopus, doi:10.1002/stc.1602.
Harvey PS, Gavin HP, Scruggs JT, Rinker JM. Determining the physical limits on semi-active control performance: A tutorial. Structural Control and Health Monitoring. 2014 Jan 1;21(5):803–816.
Journal cover image

Published In

Structural Control and Health Monitoring

DOI

EISSN

1545-2263

ISSN

1545-2255

Publication Date

January 1, 2014

Volume

21

Issue

5

Start / End Page

803 / 816

Related Subject Headings

  • Civil Engineering
  • 4005 Civil engineering
  • 0905 Civil Engineering