Skip to main content
Journal cover image

A multiobserver study of the effects of including point-of-care patient photographs with portable radiography: a means to detect wrong-patient errors.

Publication ,  Journal Article
Tridandapani, S; Ramamurthy, S; Provenzale, J; Obuchowski, NA; Evanoff, MG; Bhatti, P
Published in: Acad Radiol
August 2014

RATIONALE AND OBJECTIVES: To evaluate whether the presence of facial photographs obtained at the point-of-care of portable radiography leads to increased detection of wrong-patient errors. MATERIALS AND METHODS: In this institutional review board-approved study, 166 radiograph-photograph combinations were obtained from 30 patients. Consecutive radiographs from the same patients resulted in 83 unique pairs (ie, a new radiograph and prior, comparison radiograph) for interpretation. To simulate wrong-patient errors, mismatched pairs were generated by pairing radiographs from different patients chosen randomly from the sample. Ninety radiologists each interpreted a unique randomly chosen set of 10 radiographic pairs, containing up to 10% mismatches (ie, error pairs). Radiologists were randomly assigned to interpret radiographs with or without photographs. The number of mismatches was identified, and interpretation times were recorded. RESULTS: Ninety radiologists with 21 ± 10 (mean ± standard deviation) years of experience were recruited to participate in this observer study. With the introduction of photographs, the proportion of errors detected increased from 31% (9 of 29) to 77% (23 of 30; P = .006). The odds ratio for detection of error with photographs to detection without photographs was 7.3 (95% confidence interval: 2.29-23.18). Observer qualifications, training, or practice in cardiothoracic radiology did not influence sensitivity for error detection. There is no significant difference in interpretation time for studies without photographs and those with photographs (60 ± 22 vs. 61 ± 25 seconds; P = .77). CONCLUSIONS: In this observer study, facial photographs obtained simultaneously with portable chest radiographs increased the identification of any wrong-patient errors, without substantial increase in interpretation time. This technique offers a potential means to increase patient safety through correct patient identification.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Acad Radiol

DOI

EISSN

1878-4046

Publication Date

August 2014

Volume

21

Issue

8

Start / End Page

1038 / 1047

Location

United States

Related Subject Headings

  • United States
  • Task Performance and Analysis
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Point-of-Care Systems
  • Photography
  • Patient Identification Systems
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tridandapani, S., Ramamurthy, S., Provenzale, J., Obuchowski, N. A., Evanoff, M. G., & Bhatti, P. (2014). A multiobserver study of the effects of including point-of-care patient photographs with portable radiography: a means to detect wrong-patient errors. Acad Radiol, 21(8), 1038–1047. https://doi.org/10.1016/j.acra.2014.03.006
Tridandapani, Srini, Senthil Ramamurthy, James Provenzale, Nancy A. Obuchowski, Michael G. Evanoff, and Pamela Bhatti. “A multiobserver study of the effects of including point-of-care patient photographs with portable radiography: a means to detect wrong-patient errors.Acad Radiol 21, no. 8 (August 2014): 1038–47. https://doi.org/10.1016/j.acra.2014.03.006.
Tridandapani S, Ramamurthy S, Provenzale J, Obuchowski NA, Evanoff MG, Bhatti P. A multiobserver study of the effects of including point-of-care patient photographs with portable radiography: a means to detect wrong-patient errors. Acad Radiol. 2014 Aug;21(8):1038–47.
Tridandapani, Srini, et al. “A multiobserver study of the effects of including point-of-care patient photographs with portable radiography: a means to detect wrong-patient errors.Acad Radiol, vol. 21, no. 8, Aug. 2014, pp. 1038–47. Pubmed, doi:10.1016/j.acra.2014.03.006.
Tridandapani S, Ramamurthy S, Provenzale J, Obuchowski NA, Evanoff MG, Bhatti P. A multiobserver study of the effects of including point-of-care patient photographs with portable radiography: a means to detect wrong-patient errors. Acad Radiol. 2014 Aug;21(8):1038–1047.
Journal cover image

Published In

Acad Radiol

DOI

EISSN

1878-4046

Publication Date

August 2014

Volume

21

Issue

8

Start / End Page

1038 / 1047

Location

United States

Related Subject Headings

  • United States
  • Task Performance and Analysis
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Point-of-Care Systems
  • Photography
  • Patient Identification Systems
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Middle Aged