Skip to main content

An Inter-Projection Interpolation (IPI) Approach with Geometric Model Restriction to Reduce Image Dose in Cone Beam CT (CBCT).

Publication ,  Conference
Zhang, H; Kong, F; Ren, L; Jin, J-Y
Published in: Comput Model Objects Present Images (2014)
September 2014

Cone beam computed tomography (CBCT) imaging is a key step in image guided radiation therapy (IGRT) to improve tumor targeting. The quality and imaging dose of CBCT are two important factors. However, X-ray scatter in the large cone beam field usually induces image artifacts and degrades the image quality for CBCT. A synchronized moving grid (SMOG) approach has recently been proposed to resolve this issue and shows great promise. However, the SMOG technique requires two projections in the same gantry angle to obtain full information due to signal blockage by the grid. This study aims to develop an inter-projection interpolation (IPI) method to estimate the blocked image information. This approach will require only one projection in each gantry angle, thus reducing the scan time and patient dose. IPI is also potentially suitable for sparse-view CBCT reconstruction to reduce the imaging dose. To be compared with other state-of-the-art spatial interpolation (called inpainting) methods in terms of signal-to-noise ratio (SNR) on a Catphan and head phantoms, IPI increases SNR from 15.3dB and 12.7dB to 29.0dB and 28.1dB, respectively. The SNR of IPI on sparse-view CBCT reconstruction can achieve from 28dB to 17dB for undersample projection sets with gantry angle interval varying from 1 to 3 degrees for both phantoms.

Duke Scholars

Published In

Comput Model Objects Present Images (2014)

DOI

Publication Date

September 2014

Volume

8641

Start / End Page

12 / 23

Location

Switzerland

Related Subject Headings

  • Artificial Intelligence & Image Processing
  • 46 Information and computing sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Zhang, H., Kong, F., Ren, L., & Jin, J.-Y. (2014). An Inter-Projection Interpolation (IPI) Approach with Geometric Model Restriction to Reduce Image Dose in Cone Beam CT (CBCT). In Comput Model Objects Present Images (2014) (Vol. 8641, pp. 12–23). Switzerland. https://doi.org/10.1007/978-3-319-09994-1_2
Zhang, Hong, Fengchong Kong, Lei Ren, and Jian-Yue Jin. “An Inter-Projection Interpolation (IPI) Approach with Geometric Model Restriction to Reduce Image Dose in Cone Beam CT (CBCT).” In Comput Model Objects Present Images (2014), 8641:12–23, 2014. https://doi.org/10.1007/978-3-319-09994-1_2.
Zhang H, Kong F, Ren L, Jin J-Y. An Inter-Projection Interpolation (IPI) Approach with Geometric Model Restriction to Reduce Image Dose in Cone Beam CT (CBCT). In: Comput Model Objects Present Images (2014). 2014. p. 12–23.
Zhang, Hong, et al. “An Inter-Projection Interpolation (IPI) Approach with Geometric Model Restriction to Reduce Image Dose in Cone Beam CT (CBCT).Comput Model Objects Present Images (2014), vol. 8641, 2014, pp. 12–23. Pubmed, doi:10.1007/978-3-319-09994-1_2.
Zhang H, Kong F, Ren L, Jin J-Y. An Inter-Projection Interpolation (IPI) Approach with Geometric Model Restriction to Reduce Image Dose in Cone Beam CT (CBCT). Comput Model Objects Present Images (2014). 2014. p. 12–23.

Published In

Comput Model Objects Present Images (2014)

DOI

Publication Date

September 2014

Volume

8641

Start / End Page

12 / 23

Location

Switzerland

Related Subject Headings

  • Artificial Intelligence & Image Processing
  • 46 Information and computing sciences