Pros and cons of organ shielding for CT imaging.

Publication ,  Journal Article
Samei, E
Published in: Pediatr Radiol
October 2014

With the increased importance of CT radiation dose to health care providers, patients and the general public, there is an increased responsibility to minimize patient dose effectively. Bismuth shields offer a simple strategy to reduce dose to certain anterior radiosensitive organs such as breasts and eyes. However, in order to reduce organ dose they must be used properly; improper use can lead to an actual increase in the patient dose. They also create a proportional increase in image noise in the section of the body adjacent to the shield and further reduce the quantitative precision of CT numbers. In addition, shielding can degrade the overall efficiency (by an order of approximately 10%) of the imaging process, reducing the theoretical image quality that can be expected from a certain level of patient dose. However, in spite of their significant disadvantages, there are certain clinical situations and practice considerations that provide qualified justification for their continued use.

Duke Scholars

Published In

Pediatr Radiol

DOI

EISSN

1432-1998

Publication Date

October 2014

Volume

44 Suppl 3

Start / End Page

495 / 500

Location

Germany

Related Subject Headings

  • Tomography, X-Ray Computed
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiation Protection
  • Radiation Injuries
  • Radiation Dosage
  • Organ Specificity
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Equipment Failure Analysis
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Samei, E. (2014). Pros and cons of organ shielding for CT imaging. Pediatr Radiol, 44 Suppl 3, 495–500. https://doi.org/10.1007/s00247-014-3084-z
Samei, Ehsan. “Pros and cons of organ shielding for CT imaging.Pediatr Radiol 44 Suppl 3 (October 2014): 495–500. https://doi.org/10.1007/s00247-014-3084-z.
Samei E. Pros and cons of organ shielding for CT imaging. Pediatr Radiol. 2014 Oct;44 Suppl 3:495–500.
Samei, Ehsan. “Pros and cons of organ shielding for CT imaging.Pediatr Radiol, vol. 44 Suppl 3, Oct. 2014, pp. 495–500. Pubmed, doi:10.1007/s00247-014-3084-z.
Samei E. Pros and cons of organ shielding for CT imaging. Pediatr Radiol. 2014 Oct;44 Suppl 3:495–500.
Journal cover image

Published In

Pediatr Radiol

DOI

EISSN

1432-1998

Publication Date

October 2014

Volume

44 Suppl 3

Start / End Page

495 / 500

Location

Germany

Related Subject Headings

  • Tomography, X-Ray Computed
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiation Protection
  • Radiation Injuries
  • Radiation Dosage
  • Organ Specificity
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Equipment Failure Analysis