Comparison of 2D and 3D gamma analyses.

Publication ,  Journal Article
Pulliam, KB; Huang, JY; Howell, RM; Followill, D; Bosca, R; O'Daniel, J; Kry, SF
Published in: Med Phys
February 2014

PURPOSE: As clinics begin to use 3D metrics for intensity-modulated radiation therapy (IMRT) quality assurance, it must be noted that these metrics will often produce results different from those produced by their 2D counterparts. 3D and 2D gamma analyses would be expected to produce different values, in part because of the different search space available. In the present investigation, the authors compared the results of 2D and 3D gamma analysis (where both datasets were generated in the same manner) for clinical treatment plans. METHODS: Fifty IMRT plans were selected from the authors' clinical database, and recalculated using Monte Carlo. Treatment planning system-calculated ("evaluated dose distributions") and Monte Carlo-recalculated ("reference dose distributions") dose distributions were compared using 2D and 3D gamma analysis. This analysis was performed using a variety of dose-difference (5%, 3%, 2%, and 1%) and distance-to-agreement (5, 3, 2, and 1 mm) acceptance criteria, low-dose thresholds (5%, 10%, and 15% of the prescription dose), and data grid sizes (1.0, 1.5, and 3.0 mm). Each comparison was evaluated to determine the average 2D and 3D gamma, lower 95th percentile gamma value, and percentage of pixels passing gamma. RESULTS: The average gamma, lower 95th percentile gamma value, and percentage of passing pixels for each acceptance criterion demonstrated better agreement for 3D than for 2D analysis for every plan comparison. The average difference in the percentage of passing pixels between the 2D and 3D analyses with no low-dose threshold ranged from 0.9% to 2.1%. Similarly, using a low-dose threshold resulted in a difference between the mean 2D and 3D results, ranging from 0.8% to 1.5%. The authors observed no appreciable differences in gamma with changes in the data density (constant difference: 0.8% for 2D vs 3D). CONCLUSIONS: The authors found that 3D gamma analysis resulted in up to 2.9% more pixels passing than 2D analysis. It must be noted that clinical 2D versus 3D datasets may have additional differences--for example, if 2D measurements are made with a different dosimeter than 3D measurements. Factors such as inherent dosimeter differences may be an important additional consideration to the extra dimension of available data that was evaluated in this study.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

February 2014

Volume

41

Issue

2

Start / End Page

021710

Location

United States

Related Subject Headings

  • Software
  • Radiotherapy, Intensity-Modulated
  • Radiotherapy Planning, Computer-Assisted
  • Quality Control
  • Nuclear Medicine & Medical Imaging
  • Humans
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Pulliam, K. B., Huang, J. Y., Howell, R. M., Followill, D., Bosca, R., O’Daniel, J., & Kry, S. F. (2014). Comparison of 2D and 3D gamma analyses. Med Phys, 41(2), 021710. https://doi.org/10.1118/1.4860195
Pulliam, Kiley B., Jessie Y. Huang, Rebecca M. Howell, David Followill, Ryan Bosca, Jennifer O’Daniel, and Stephen F. Kry. “Comparison of 2D and 3D gamma analyses.Med Phys 41, no. 2 (February 2014): 021710. https://doi.org/10.1118/1.4860195.
Pulliam KB, Huang JY, Howell RM, Followill D, Bosca R, O’Daniel J, et al. Comparison of 2D and 3D gamma analyses. Med Phys. 2014 Feb;41(2):021710.
Pulliam, Kiley B., et al. “Comparison of 2D and 3D gamma analyses.Med Phys, vol. 41, no. 2, Feb. 2014, p. 021710. Pubmed, doi:10.1118/1.4860195.
Pulliam KB, Huang JY, Howell RM, Followill D, Bosca R, O’Daniel J, Kry SF. Comparison of 2D and 3D gamma analyses. Med Phys. 2014 Feb;41(2):021710.

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

February 2014

Volume

41

Issue

2

Start / End Page

021710

Location

United States

Related Subject Headings

  • Software
  • Radiotherapy, Intensity-Modulated
  • Radiotherapy Planning, Computer-Assisted
  • Quality Control
  • Nuclear Medicine & Medical Imaging
  • Humans
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering