Clinical outcomes after implantation of a centrifugal flow left ventricular assist device and concurrent cardiac valve procedures.

Publication ,  Journal Article
Milano, C; Pagani, FD; Slaughter, MS; Pham, DT; Hathaway, DR; Jacoski, MV; Najarian, KB; Aaronson, KD; ADVANCE Investigators,
Published in: Circulation
September 9, 2014

BACKGROUND: Cardiac valve procedures are commonly performed concurrently during implantation of left ventricular assist devices, but the added procedural risk has not been studied in detail. METHODS AND RESULTS: Data from patients receiving the HeartWare Ventricular Assist Device in the ADVANCE bridge to transplant (BTT) trial and continued access protocol were reviewed. Of 382 consecutive patients who completed follow-up between August 2008 and June 2013 (mean time on support 389 days, median 271 days), 262 (68.6%) underwent isolated HeartWare Ventricular Assist Device implantation, 75 (19.6%) a concurrent valve procedure, and 45 (11.8%) concurrent nonvalvular procedures. Of the concurrent valve procedures, 56 were tricuspid, 13 aortic, and 6 mitral. Survival was similar between groups (79% for concurrent valve procedures and 85% for HeartWare Ventricular Assist Device only at 1 year; P=0.33). Concurrent valve procedures were also associated with increased unadjusted early right heart failure (RHF). A multivariable analysis for death and RHF (121 total events) identified female sex (odds ratio=2.0 [95% confidence interval, 1.2-3.3; P=0.0053]) and preimplant tricuspid regurgitation severity (odds ratio=2.9 [95% confidence interval, 1.8-4.8, P<0.0001]) as independent predictors while concurrent tricuspid valve procedures (TVP) were not predictors. Furthermore, patients with significant preimplant tricuspid regurgitation who did not receive a TVP experienced an increased rate of late RHF compared with those who received TVP (0.19 versus 0.05 events per patient-year, respectively; P=0.024). CONCLUSIONS: Compared with HeartWare Ventricular Assist Device alone, survival was equivalent for the concurrent valve procedure group. Tricuspid regurgitation severity was the most important predictor of increased postoperative RHF, and concurrent TVP was not an independent predictor of RHF overall. Concurrent TVP may reduce the rate of late RHF for patients with significant preimplant tricuspid insufficiency. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00751972.

Duke Scholars

Published In

Circulation

DOI

EISSN

1524-4539

Publication Date

September 9, 2014

Volume

130

Issue

11 Suppl 1

Start / End Page

S3 / 11

Location

United States

Related Subject Headings

  • Tricuspid Valve Insufficiency
  • Treatment Outcome
  • Retrospective Studies
  • Postoperative Complications
  • Pericardium
  • Multicenter Studies as Topic
  • Middle Aged
  • Male
  • Humans
  • Heart-Assist Devices
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Milano, C., Pagani, F. D., Slaughter, M. S., Pham, D. T., Hathaway, D. R., Jacoski, M. V., … ADVANCE Investigators, . (2014). Clinical outcomes after implantation of a centrifugal flow left ventricular assist device and concurrent cardiac valve procedures. Circulation, 130(11 Suppl 1), S3-11. https://doi.org/10.1161/CIRCULATIONAHA.113.007911
Milano, Carmelo, Francis D. Pagani, Mark S. Slaughter, Duc Thinh Pham, David R. Hathaway, Mary V. Jacoski, Kevin B. Najarian, Keith D. Aaronson, and Keith D. ADVANCE Investigators. “Clinical outcomes after implantation of a centrifugal flow left ventricular assist device and concurrent cardiac valve procedures.Circulation 130, no. 11 Suppl 1 (September 9, 2014): S3-11. https://doi.org/10.1161/CIRCULATIONAHA.113.007911.
Milano C, Pagani FD, Slaughter MS, Pham DT, Hathaway DR, Jacoski MV, et al. Clinical outcomes after implantation of a centrifugal flow left ventricular assist device and concurrent cardiac valve procedures. Circulation. 2014 Sep 9;130(11 Suppl 1):S3-11.
Milano, Carmelo, et al. “Clinical outcomes after implantation of a centrifugal flow left ventricular assist device and concurrent cardiac valve procedures.Circulation, vol. 130, no. 11 Suppl 1, Sept. 2014, pp. S3-11. Pubmed, doi:10.1161/CIRCULATIONAHA.113.007911.
Milano C, Pagani FD, Slaughter MS, Pham DT, Hathaway DR, Jacoski MV, Najarian KB, Aaronson KD, ADVANCE Investigators. Clinical outcomes after implantation of a centrifugal flow left ventricular assist device and concurrent cardiac valve procedures. Circulation. 2014 Sep 9;130(11 Suppl 1):S3-11.

Published In

Circulation

DOI

EISSN

1524-4539

Publication Date

September 9, 2014

Volume

130

Issue

11 Suppl 1

Start / End Page

S3 / 11

Location

United States

Related Subject Headings

  • Tricuspid Valve Insufficiency
  • Treatment Outcome
  • Retrospective Studies
  • Postoperative Complications
  • Pericardium
  • Multicenter Studies as Topic
  • Middle Aged
  • Male
  • Humans
  • Heart-Assist Devices