Ultrasound evaluation of glaucoma drainage devices in children.

Publication ,  Journal Article
Baig, NB; Lin, AA; Freedman, SF
Published in: J AAPOS
June 2015

This study evaluated B-scan ultrasound as a technique for assessing glaucoma drainage device (GDD) patency/function in refractory pediatric glaucoma. We retrospectively evaluated 70 eyes of 52 patients after Ahmed (n = 40 eyes), Baerveldt (n = 27 eyes) and Molteno (n = 5 eyes) GDD implantation; 2 eyes each had 2 GDDs. Median age was 6.5 years. Glaucoma diagnoses included primary congenital glaucoma (n = 19) and secondary glaucoma associated with aphakia (n = 16), aniridia (n = 5), Peters anomaly (n = 3), uveitis (n = 2), and other conditions (n = 7). B-scan ultrasound evaluation proved helpful to clinical assessment when the GDD tube was not seen because of opaque corneas (n = 20 eyes), the bleb was not visualized (n = 21 eyes), or IOP was elevated (n = 28 eyes). Ultrasound findings suggesting a nonpatent or malfunctioning GDD were further confirmed by subsequent intraoperative bleb needling (n = 2 eyes) and GDD revision (n = 7 eyes). B-scan ultrasound evaluation can serve as a useful adjunct in evaluating GDD patency/function in selected eyes with refractory pediatric glaucoma and may aid in clinical management.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J AAPOS

DOI

EISSN

1528-3933

Publication Date

June 2015

Volume

19

Issue

3

Start / End Page

281 / 284

Location

United States

Related Subject Headings

  • Young Adult
  • Ultrasonography
  • Retrospective Studies
  • Prosthesis Implantation
  • Postoperative Complications
  • Ophthalmology & Optometry
  • Male
  • Intraocular Pressure
  • Infant
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Baig, N. B., Lin, A. A., & Freedman, S. F. (2015). Ultrasound evaluation of glaucoma drainage devices in children. J AAPOS, 19(3), 281–284. https://doi.org/10.1016/j.jaapos.2015.02.001
Baig, Nafees B., Alice A. Lin, and Sharon F. Freedman. “Ultrasound evaluation of glaucoma drainage devices in children.J AAPOS 19, no. 3 (June 2015): 281–84. https://doi.org/10.1016/j.jaapos.2015.02.001.
Baig NB, Lin AA, Freedman SF. Ultrasound evaluation of glaucoma drainage devices in children. J AAPOS. 2015 Jun;19(3):281–4.
Baig, Nafees B., et al. “Ultrasound evaluation of glaucoma drainage devices in children.J AAPOS, vol. 19, no. 3, June 2015, pp. 281–84. Pubmed, doi:10.1016/j.jaapos.2015.02.001.
Baig NB, Lin AA, Freedman SF. Ultrasound evaluation of glaucoma drainage devices in children. J AAPOS. 2015 Jun;19(3):281–284.
Journal cover image

Published In

J AAPOS

DOI

EISSN

1528-3933

Publication Date

June 2015

Volume

19

Issue

3

Start / End Page

281 / 284

Location

United States

Related Subject Headings

  • Young Adult
  • Ultrasonography
  • Retrospective Studies
  • Prosthesis Implantation
  • Postoperative Complications
  • Ophthalmology & Optometry
  • Male
  • Intraocular Pressure
  • Infant
  • Humans